Services
Tools
Products
>
Temperature
>
Dial thermometers – Range of 21 models
Temperature
strumenti-temperatura
WIKA

Dial thermometers – Range of 21 models

Dial thermometers with scale ranges from -200 to +700 °C. 21 models from WIKA, also with ATEX, IECEx, CSA approvals: filters, datasheet and quote request for each model.

ATEX
IECEx
CSA
IA
CE
EAC
DNV
UKCA
Description
Technical Specifications
Applications
Download
Datasheets

Dial thermometers with scale ranges from -200 to +700 °C

Our dial thermometers work on the bimetal, expansion or gas actuation principle. This enables scale ranges of -200 to +700 °C in different class accuracies, response times and resilience to environmental influences. Diverse connection designs, stem diameters and individual stem lengths enable a flexible measuring location design. Dial thermometers with remote capillaries are particularly versatile. All thermometers are suited for operation in a thermowell if necessary.

What is a dial thermometer?

The functionality is dependent upon the type of the thermometer. The WIKA product portfolio includes bimetal thermometers, gas-actuated thermometers, expansion thermometers, machine glass thermometers and also thermomanometers.

What is the difference between bimetal and gas-actuated thermometers?

With bimetal thermometers the temperature measurement is achieved via a mechanical deformation which transmits the movement, via a pointer shaft, to the pointer of the thermometer. With gas-actuated thermometers, on the other hand, the entire measuring system is filled with an inert gas under pressure. The measured temperature is transmitted via a capillary.

What is the most suitable dial thermometer for my application?

The following criteria are suitable for selecting the right dial thermometers for your process:

• Response timeWhen it comes to speed, you will get the measuring result faster with a gas-actuated thermometer than with a bimetal thermometer. A gas-actuated thermometer, for a temperature measurement from 10 °C to 90 °C, indicates the end value after about 30 seconds. Around 60 seconds quicker than a bimetal thermometer. It should be noted that thermowells can significantly affect the response time of thermometers. How seriously depends on both the wall thickness and the type of material of the thermowell.

• Process temperatureUsually, for scale ranges from -70 °C up to +600 °C, bimetal thermometers are used. If these are filled with liquid to protect them from high shock and vibration loads, the maximum temperature is reduced to +250 °C. Gas-actuated thermometers, on the other hand, are designed for process temperatures from -200 °C up to +700 °C. However, these are influenced by the ambient temperature, which is why the thermometer must be dimensioned accordingly for accurate measuring results.

• Remote capillaryTo measure the temperature in places that are difficult to access or far away, only gas-actuated thermometers can be used. WIKA guarantees accuracy class 1 for the corresponding measuring instrument for a capillary length of up to 60 m.

Where are dial thermometers used?

The extensive product range of WIKA dial thermometers covers the widest variety of applications. Both bimetal thermometers and gas-actuated thermometers reliably measure temperature in the fields of heating, ventilation and air-conditioning technology, machine building and plant construction, in vessel construction and equipment manufacturing, for food and beverages, oil and gas, the chemical and petrochemical industry, power generation and water/wastewater industry, and also in the food industry and sanitary applications.

What is an expansion thermometer?

WIKA expansion thermometers can be used universally in the fields of refrigeration and air-conditioning, in machine building or in the food and beverage industry. Thermometers of this type can be installed almost anywhere and, in the version with a remote capillary, are also suitable for measurement over long distances.

What is a thermomanometer?

Thermomanometers from WIKA usually consist of a combined display for pressure and temperature and are mainly used in heating systems or in combi-boilers with hot water and heating. With remote capillary, they can measure pressures up to 16 bar and also temperatures up to 150 °C over long distances, without problem.

What is a machine glass thermometer?

Machine thermometers, or also called machine glass thermometers, are particularly insensitive to vibration and are mainly used in industrial applications, such as in machine building and vessel construction, in central and large heating systems or in plant construction. Since there is no mechanical wear, glass thermometers feature particularly high accuracy and an extremely long service life.

No items found.
# General Brand: WIKA Category: Dial thermometers Available models: 21 # Explosion protection Ex approvals: ATEX, IECEx, CSA, EAC Types of protection: Ex h (constructional safety, non-electrical), Ex i (intrinsic safety)
{"modelli":{"f":[["Capillare",["",""]],["Valore iniziale della scala esterna",["Al di sotto di 0°","Superiore a 0°","Al di sotto di 0°","Superiore a 0°"]],["Diametro nominale",["≤ 1 ½","2","2 ½","3","4","≥ 6","≤ 40","50","63","80","100","≥ 160"]],["Principio di misura",["Bimetallico","A espansione di liquido","A espansione di gas"]],["Tempo di risposta",["< 3 minuti","> 3 minuti"]],["Protezione antideflagrante",["ATEX","EAC Ex"]],["Output",["Local indication only","Wireless","Switch contacts"]],["Wetted parts material",["Stainless steel","Plastic"]],["Approvals",["ATEX","IECEx","CSA","EAC"]]],"r":[["THM10","Bimetal thermomanometer Eco – For pressure and temperature measurement",[[1],[1],[0,1,2,3,4,5,8,9],[0],[1],[0,1],[0],[],[]],0,"Data-sheets/Pressure/Pressure-gauges/ds_pm0124_en_co.pdf",""],["100.10, 100.12","Bimetal thermomanometer – For pressure and temperature measurement, NS 63 [2 ½\"] and NS 80 [3\"]",[[],[],[],[],[],[],[0],[],[]],1,"Data-sheets/Pressure/Pressure-gauges/ds_pm0123_en_co.pdf",""],["MFT","Thermomanometer – For remote mounting with capillaries, NS 40 [1 ½\"], NS 42 [1.7\"] and NS 52 [2.1\"]",[[0,1],[0,1],[0,1,2,3,4,5,6,7],[1],[1],[0,1],[0],[],[]],2,"Data-sheets/Pressure/Pressure-gauges/ds_pm0120_en_co.pdf",""],["TGU73.100","Gas-actuated thermometer for connection to WIKA radio unit – Stainless steel version",[[0,1],[0,1,2,3],[0,1,2,3,4,5,6,7,8,9,10,11],[0,1,2],[0,1],[0,1],[1],[0],[0,1,2]],3,"Data-sheets/Temperature/Dial-thermometers/ds_tv1713_en_co.pdf","ATEX, IECEx, CSA"],["A43","Bimetal thermometer – For heating technology",[[1],[0,1],[0,1,2,3,4,5,8,9,10],[0],[1],[0,1],[0],[],[]],4,"Data-sheets/Temperature/Dial-thermometers/ds_tm4301_en_co.pdf",""],["TG53","Bimetal thermometer – Process version per ASME B40.200",[[1],[0,1,2,3],[3,4,5,8,9,10,11],[0],[1],[0,1],[0],[],[0,3]],5,"Data-sheets/Temperature/Dial-thermometers/ds_tm5302_en_co.pdf","ATEX, EAC"],["A48","Bimetal thermometer – For air-conditioning and refrigeration systems",[[1],[0,1],[0,1,2,3,4,5,8,9,10],[0],[1],[0,1],[0],[],[]],6,"Data-sheets/Temperature/Dial-thermometers/ds_tm4801_en_co.pdf",""],["TG54","Bimetal thermometer – Process version per EN 13190",[[1],[0,1,2,3],[8,9,10,11],[0],[1],[0,1],[0],[],[0,3]],7,"Data-sheets/Temperature/Dial-thermometers/ds_tm5402_en_co.pdf","ATEX, EAC"],["TG58SA","Bimetal thermometer – For sanitary applications",[[1],[0,1,2,3],[2,3,4,8,9,10],[0],[1],[0,1],[0],[],[0,3]],8,"Data-sheets/Temperature/Dial-thermometers/ds_tm5801_en_co.pdf","ATEX, EAC"],["A50","Bimetal thermometer – Standard version",[[1],[0,1],[0,1,2,3,4,5,8,9,10,11],[0],[1],[0,1],[0],[],[]],9,"Data-sheets/Temperature/Dial-thermometers/ds_tm5003_en_co.pdf",""],["55","Bimetal thermometer – For the process industry per EN 13190, premium version",[[1],[0,1,2,3],[8,10,11],[0],[1],[0,1],[0],[0],[0,3]],10,"Data-sheets/Temperature/Dial-thermometers/ds_tm5501_en_co.pdf","ATEX, EAC"],["A52, R52","Bimetallic thermometer – For industrial applications",[[1],[0,1,3],[0,1,2,3,4,5,6,7,8,9,10,11],[0],[1],[0,1],[0],[0],[]],11,"Data-sheets/Temperature/Dial-thermometers/ds_tm5201_en_co.pdf",""],["73","Gas-actuated thermometer – Stainless steel version",[[0,1],[0,1,2,3],[10,11],[2],[0,1],[0,1],[0],[0],[0,3]],12,"Data-sheets/Temperature/Dial-thermometers/ds_tm7301_en_co.pdf","ATEX, EAC"],["70","Expansion thermometer – Stainless steel version",[[0,1],[0,1,3],[0,1,2,3,4,5,8,10,11],[1],[1],[0,1],[0],[0],[]],13,"Data-sheets/Temperature/Dial-thermometers/ds_tm8101_en_co.pdf",""],["A46","Bimetal thermometer – For heating technology, special versions",[[1],[0,1],[0,1,2,3,4,5,6,7,8,9,10,11],[0],[1],[0,1],[0],[],[]],14,"Data-sheets/Temperature/Dial-thermometers/ds_tm4602_en_co.pdf",""],["74","Gas-actuated thermometer for sanitary applications – Stainless steel version",[[1],[0,1,2,3],[10],[2],[0],[0,1],[2],[0],[0,3]],15,"Data-sheets/Temperature/Dial-thermometers/ds_tm7401_en_co.pdf","ATEX, EAC"],["TF58, TF59","Expansion thermometer",[[0,1],[0,1],[0,1,2,3,4,5,6,7,8,9,10,11],[1],[1],[0,1],[0],[1],[]],16,"Data-sheets/Temperature/Dial-thermometers/ds_tm8002_en_co.pdf",""],["75","Gas-actuated thermometer, highly vibration resistant – Stainless steel version",[[0,1],[1,3],[10],[2],[0],[0,1],[0],[0],[]],17,"Data-sheets/Temperature/Dial-thermometers/ds_tm7501_en_co.pdf",""],["IFC","Expansion thermometer – For industrial applications",[[0,1],[0,1],[0,1,2,3,4,5,6,7,8,9,10],[1],[1],[0,1],[0],[],[]],18,"Data-sheets/Temperature/Dial-thermometers/ds_tm8001_en_co.pdf",""],["32","Machine glass thermometer – V shape",[[1],[0,1],[0,1,2,3,4,5,6,7,8,9,10,11],[1],[1],[0,1],[0],[],[]],19,"Data-sheets/Temperature/Dial-thermometers/ds_tm3202_en_co.pdf",""],["A2G-61","Analogue ventilation duct temperature sensor",[[0,1],[0,1,2,3],[0,1,2,3,4,5,6,7,8,9,10,11],[0,1,2],[0,1],[0,1],[0],[],[]],20,"Data-sheets/Temperature/Dial-thermometers/ds_tm4802_en_co.pdf",""]],"s":{"u":"https://cdn.prod.website-files.com/6aa55eca30c5bd4a1e486a4c/6ade220dab3cad773e8e7dde_mfw-termometri-a-quadrante.jpg","c":12}}}
No items found.
No applications listed.