Services
Tools
Products
>
Temperature
>
Thermocouples – Range of 23 models
Temperature
strumenti-temperatura
WIKA

Thermocouples – Range of 23 models

Thermocouples for temperature measurement up to 1,700 °C. 23 models from WIKA, also with ATEX, IECEx, CSA approvals: filters, datasheet and quote request for each model.

ATEX
IECEx
CSA
FM
INMETRO
NEPSI
CCC
EAC
KCs
CCOE/PESO
ECAS-Ex
CE
DNV
KOSHA
UKCA
Description
Technical Specifications
Applications
Download
Datasheets

Thermocouples for temperature measurement up to 1,700 °C

Thermocouples are temperature sensors that generate a voltage directly dependent on temperature. Compared to resistance thermometers, they are particularly suited for high temperatures up to 1,700 °C. Instrument designs from mineral-insulated sheathed cable are very resistant against extremely high vibration loads (depending on instrument model, sensor element and wetted materials). The accuracy classes 1 and 2 apply for thermocouples in accordance with IEC 60584 as well as the standard and special classes in accordance with ASTM E230.

What is a thermocouple including thermowell?

A thermowell keeps aggressive substances and other harmful influences away from the temperature probe itself. Operating personnel and the environment are thus protected. Thermowell variants are available with flanges, threaded or for welding in. With high-temperature sensors, the thermoelectric wires of the thermocouple are built into the thermowell. Thus, extremely high temperatures can be measured. Instruments for flue gas temperature measurement are suitable for temperature measurement in gaseous media in the low pressure range (up to approx. 1 bar).

What is a thermocouple for additional thermowell?

These thermocouples can be combined with a large number of thermowell designs. Through the individual build-up of connection head, sensor, insertion length, etc., you can have a thermometer suited to each thermowell dimension and each application.

What is a thermocouple for direct installation into the process?

These instruments are used whenever a temperature measurement must be made directly in the process. Thermometers without thermowells are suited for all applications where there is no chemically aggressive media and no abrasion.

Thermocouples with surface probes

For surface temperature measurement, within the WIKA range you will find thermocouples with surface probes. Various designs enable measurements on flat surfaces - including inside combustion furnaces and on pipes in industrial and laboratory applications. These temperature sensors can also be mounted directly into bored holes.

Thermocouples for the plastics industry

These hot-runner thermocouples are designed specifically for use in the plastics industry. They are suitable for measuring tasks where they are press-fitted into a grooved channel along the machined parts or where the metal sensor tip is fitted directly into a drilled hole.

What is a high-temperature thermometer?

The WIKA high-temperature thermometers of the model series TC80 are used in order to measure extreme high temperatures. The large number of process connections enables the high-temperature thermometers to be mounted directly in the process. For example, stop flanges, fixed welded flanges and, also, threaded bushings are available. For particularly critical applications, versions with inert gas or compressed-air flushing or with a pressure-tight sealing are used. Transmitters can also be installed, optionally, in the high-temperature thermometers of the TC80 series.

Where are high-temperature thermometers used?

High-temperature thermometers are used with extremely high process temperatures up to a maximum of +1,700 °C / +3,100 °F. For example, in blast furnaces, hot blast stoves, in waste incineration or in the glass, porcelain and ceramics industries. The thermowell made of heat-resistant steel or special ceramic materials protects the thermocouple during the process and increases the service life of the sensors.

Customer-specific solutions

Whether in the high-pressure range, e.g. for use in polyethylene synthesis, or as multipoint thermocouple for the chemical industry. The wide WIKA product portfolio offers a multitude of customer-specific solutions.

No items found.
# General Brand: WIKA Category: Thermocouples Available models: 23 # Explosion protection Ex approvals: ATEX, IECEx, CSA, FM, INMETRO, NEPSI, CCC, EAC, KCs, KOSHA, PESO, ECAS-Ex Types of protection: Ex d (flameproof enclosure), Ex e (increased safety), Ex i (intrinsic safety), Ex n, Ex t (protection by enclosure)
{"modelli":{"f":[["Massima temperatura del fluido",["+400°C","+800°C","+1200°C","+1600°C","+1700°C","+752°F","+1400°F","+2300°F","+2700°F","+3100°F"]],["Costruzione della sonda",["Sensore di temperatura senza pozzetto / tubo di protezione","Sensore di temperatura con pozzetto / tubo di protezione","Assieme sensore di temperatura con pozzetto aggiuntivo"]],["Esecuzione della sonda",["Sensore con testa di connessione","Sensore con uscita cavo e filettatura","Sensore con cavo plug-in, con raccordo di compressione opzionale","Sensore con uscita cavo con attacco al processo a baionetta","Sensore superficiale con cavo","Inserto di misura","Con testa di connessione, con tubo di protezione filettato ricavato da tubo","Con testa di connessione, con tubo di protezione flangiato ricavato da tubo","Sensore di temperatura per gas di scarico con tubo di protezione in metallo","Termocoppia per alte temperature con tubo di protezione in ceramica","Con testa di connessione e tubo di estensione, inserto di misura a molla","Con percorso fiamma in testina (Ex d), tubo di estensione, inserto di misura a molla","Con testa di connessione (Ex d), percorso fiamma nel tubo, inserto di misura a molla"]],["Display digitale",["Nella testa di connessione","Nella custodia alla fine del cavo"]],["Connessione elettrica",["Morsetti a vite","Connettore","Fili di connessione"]],["Segnale di uscita",["Termocoppia","4 … 20 mA","HART® (4 … 20 mA)","PROFIBUS® PA","FOUNDATION™ Fieldbus"]],["Wetted parts material",["Plastic","Special materials","Stainless steel"]],["Approvals",["ATEX","IECEx","CSA","FM","INMETRO","NEPSI","CCC","EAC","KCs","KOSHA","PESO","ECAS-Ex"]]],"r":[["TC10-0","Thermocouple – Industrial assembly",[[0,1,2,5,6,7],[2],[0,1,2,3,4,5,6,7,8,9,10,11],[0],[0],[0,1,2,3,4],[],[0,1,2,3,4,5,6,7,8,10,11]],0,"Data-sheets/Temperature/Thermocouples/ds_te6601_en_co.pdf","ATEX, IECEx, CSA, FM, INMETRO, NEPSI, CCC, EAC, KCs, PESO, ECAS-Ex"],["TC10-A","Measuring insert – For thermocouple",[[0,1,2,5,6,7],[0],[5,6,7,8,9,10,11,12],[],[0],[0,1,2,3,4],[],[0,1,4,5,6,7,8,10,11]],1,"Data-sheets/Temperature/Thermocouples/ds_te6501_en_co.pdf","ATEX, IECEx, INMETRO, NEPSI, CCC, EAC, KCs, PESO, ECAS-Ex"],["TC10-B","Thermocouple – For additional thermowell",[[0,1,2,5,6,7],[2],[0,1,2,3,4,5,6,7,8,9,10],[0],[0],[0,1,2,3,4],[],[0,1,4,5,6,7,8,10,11]],2,"Data-sheets/Temperature/Thermocouples/ds_te6502_en_co.pdf","ATEX, IECEx, INMETRO, NEPSI, CCC, EAC, KCs, PESO, ECAS-Ex"],["TC10-C","Threaded thermocouple – With protection tube",[[0,1,2,5,6],[1],[0,1,2,3,4,5,6,10,11,12],[0],[0],[0,1,2,3,4],[],[0,1,4,5,6,7,8,10,11]],3,"Data-sheets/Temperature/Thermocouples/ds_te6503_en_co.pdf","ATEX, IECEx, INMETRO, NEPSI, CCC, EAC, KCs, PESO, ECAS-Ex"],["TC10-D","Threaded thermocouple – Miniature design",[[0,5],[1],[0,1,2,3,4,5,6,10,11,12],[],[0],[0,1],[],[0,1,4,5,6,7,8,10,11]],4,"Data-sheets/Temperature/Thermocouples/ds_te6504_en_co.pdf","ATEX, IECEx, INMETRO, NEPSI, CCC, EAC, KCs, PESO, ECAS-Ex"],["TC10-F","Flanged thermocouple – With protection tube",[[0,1,2,5,6],[1],[0,1,2,3,4,5,7,10,11,12],[0],[0],[0,1,2,3,4],[],[0,1,4,5,6,7,8,10,11]],5,"Data-sheets/Temperature/Thermocouples/ds_te6506_en_co.pdf","ATEX, IECEx, INMETRO, NEPSI, CCC, EAC, KCs, PESO, ECAS-Ex"],["TC10-H","Thermocouple – Without thermowell",[[0,1,2,5,6],[0],[0,6,7,8,9,10,11,12],[0],[0],[0,1,2,3,4],[],[0,1,4,5,6,7,8,10,11]],6,"Data-sheets/Temperature/Thermocouples/ds_te6508_en_co.pdf","ATEX, IECEx, INMETRO, NEPSI, CCC, EAC, KCs, PESO, ECAS-Ex"],["TC10-L","Thermocouple – For additional thermowell, flameproof enclosure (Ex d)",[[0,1,2,5,6,7],[2],[0,1,2,3,4,5,6,7,8,9,11],[0],[0],[0,1,2,3,4],[],[0,1,4,5,6,7,11]],7,"Data-sheets/Temperature/Thermocouples/ds_te6512_en_co.pdf","ATEX, IECEx, INMETRO, NEPSI, CCC, EAC, ECAS-Ex"],["TC12-A","Measuring insert for process thermocouple",[[0,1,2,5,6],[0],[5,6,7,8,9,10,11,12],[],[2],[0],[],[0,1,4,5,6,7,8,10,11]],8,"Data-sheets/Temperature/Thermocouples/ds_te6516_en_co.pdf","ATEX, IECEx, INMETRO, NEPSI, CCC, EAC, KCs, PESO, ECAS-Ex"],["TC12-B, TC12-M","Process thermocouple – For additional thermowell or basis module",[[],[],[],[],[],[],[],[0,1,2,3,4,5,6,7,8,10,11]],9,"Data-sheets/Temperature/Thermocouples/ds_te6517_en_co.pdf","ATEX, IECEx, CSA, FM, INMETRO, NEPSI, CCC, EAC, KCs, PESO, ECAS-Ex"],["TC40","Cable thermocouple",[[0,1,2,5,6],[0],[1,2,6,7,8,9,10,11,12],[1],[0,1,2],[0,1,2,3,4],[0,1],[0,1,2,4,5,6,7,8,10,11]],10,"Data-sheets/Temperature/Thermocouples/ds_te6540_en_co.pdf","ATEX, IECEx, CSA, INMETRO, NEPSI, CCC, EAC, KCs, PESO, ECAS-Ex"],["TC46","Hot runner thermocouple",[[0,1,5,6],[0],[2,6,7,8,9,10,11,12],[],[2],[0],[0,1,2],[]],11,"Data-sheets/Temperature/Thermocouples/ds_te6546_en_co.pdf",""],["TC47-AB","Adjustable bayonet thermocouple – For the plastics machinery industry, spring-loaded design",[[0,5],[0],[3,6,7,8,9,10,11,12],[],[1,2],[0],[2],[]],12,"Data-sheets/Temperature/Thermocouples/ds_te6720_en_co.pdf",""],["TC50","Surface thermocouple",[[0,1,2,5,6],[0],[4,6,7,8,9,10,11,12],[1],[0,1,2],[0,1,2,3,4],[0,1],[0,1,2,3,4,5,6,7,8,10,11]],13,"Data-sheets/Temperature/Thermocouples/ds_te6550_en_co.pdf","ATEX, IECEx, CSA, FM, INMETRO, NEPSI, CCC, EAC, KCs, PESO, ECAS-Ex"],["TC52-M","Magnetic surface thermocouple – For high temperatures",[[0,1,5],[0],[4,6,7,8,9,10,11,12],[1],[2],[0,1,2,3,4],[],[0,1,4,7]],14,"Data-sheets/Temperature/Thermocouples/ds_te6652_en_co.pdf","ATEX, IECEx, INMETRO, EAC"],["TC53","Bayonet thermocouple",[[0,1,2,5,6],[0],[3,6,7,8,9,10,11,12],[],[1,2],[0],[],[0,1,4,5,6,7,8,10,11]],15,"Data-sheets/Temperature/Thermocouples/ds_te6553_en_co.pdf","ATEX, IECEx, INMETRO, NEPSI, CCC, EAC, KCs, PESO, ECAS-Ex"],["TC80","High-temperature thermometer – Thermocouple straight version per DIN 50446",[[0,1,2,3,4,5,6,7,8,9],[1],[0,1,2,3,4,5,8,9,10,11,12],[],[0],[0,1,2,3,4],[],[0]],16,"Data-sheets/Temperature/Thermocouples/ds_te6580_en_co.pdf","ATEX"],["TC81","Thermocouple for flue gas temperature measurements – With protection tube model TW81",[[0,1,2,5,6],[1],[0,1,2,3,4,5,8,10,11,12],[],[0],[0,1,2,3,4],[],[0,1,4,5,6,7,8,10]],17,"Data-sheets/Temperature/Thermocouples/ds_te6581_en_co.pdf","ATEX, IECEx, INMETRO, NEPSI, CCC, EAC, KCs, PESO"],["TC82","High-temperature thermocouple",[[0,1,2,3,4,5,6,7,8,9],[1],[0,1,2,3,4,5,9,10,11,12],[],[0],[0,1,2],[],[0,1,5,7]],18,"Data-sheets/Temperature/Thermocouples/ds_te6582_en_co.pdf","ATEX, IECEx, NEPSI, EAC"],["TC83","Sapphire-design thermocouple – High-temperature thermocouple",[[0,1,2,3,4,5,6,7,8,9],[1],[0,1,2,3,4,5,9,10,11,12],[],[0],[0],[],[0,1,5,7]],19,"Data-sheets/Temperature/Thermocouples/ds_te6583_en_co.pdf","ATEX, IECEx, NEPSI, EAC"],["TC84","Sapphire-design thermocouple – For high-temperature measurements with safety chamber",[[0,1,2,3,4,5,6,7,8,9],[1],[0,1,2,3,4,5,9,10,11,12],[],[0],[0],[],[0,1,7,9,11]],20,"Data-sheets/Temperature/Thermocouples/ds_te6584_en_co.pdf","ATEX, IECEx, EAC, KOSHA, ECAS-Ex"],["TC85","Measuring insert – For high-temperature thermocouple",[[0,1,2,3,4,5,6,7,8,9],[0],[5,6,7,8,9,10,11,12],[],[0],[0,1,2,3,4],[],[]],21,"Data-sheets/Temperature/Thermocouples/ds_te6685_en_co.pdf",""],["TC90","High-pressure thermocouple",[[0,5,6,7,8,9],[],[0,1,2,3,4,5,6,7,8,9,10,11,12],[],[0,2],[0,1,2,3,4],[],[0,1,2,4,5,6,7,8,10]],22,"Data-sheets/Temperature/Thermocouples/ds_te6590_en_co.pdf","ATEX, IECEx, CSA, INMETRO, NEPSI, CCC, EAC, KCs, PESO"]],"s":{"u":"https://cdn.prod.website-files.com/6aa55eca30c5bd4a1e486a4c/6ade220d67bf622c088fa224_mfw-termocoppie.jpg","c":12}}}
No items found.
No applications listed.