Zone 1
Explosive gas atmosphere likely to occur in normal operation
Zone 2
Explosive gas atmosphere unlikely to occur and, if it does, only for a short period
Zone 21
Explosive dust atmosphere likely to occur in normal operation
Zone 22
Explosive dust atmosphere unlikely to occur and, if it does, only for a short period
# General
Type: AC/DC power supply in flameproof enclosure
Input: 85–264 Vac
Output: 24 Vdc · 24 W
No-load consumption: max 300 mW
# Certifications
ATEX/IECEx: II 2(1)G Ex db mb [ia Ga] IIC T6…T4 Gb · II 2(1)D Ex mb tb [ia Da] IIIC T110…T140 °C Db · I M2(M1) (SWS only)
# Mechanical
Enclosure: Powder-coated aluminium (SWA) · Electropolished AISI 316 CF8M stainless steel (SWS)
Cable entries: 4 × 3/4" NPT-F · 4 × M25x1.5 (SWA only)
Ingress protection: IP66/68
Mounting: KM-01 pole kit · KM-02 wall kit
Weight: 2.1 kg (SWA) · 4.7 kg (SWS)
# Environmental
Ambient temperature: -40 °C to +74 °C SWA · -40 °C to +68 °C SWS
{"v":1,"marca":"","colonne":[{"nome":"Enclosure","valori":["Painted aluminium (SWA)","Electropolished AISI 316 stainless steel (SWS)"]},{"nome":"Cable entries","valori":["4 × 3/4\" NPT-F","4 × M25x1.5"]},{"nome":"Approvals","valori":["ATEX/IECEx gas and dust","ATEX/IECEx gas, dust and mining"]}],"righe":[["SWAE1000-421X0",0,0,0,21],["SWAE1000-441X0",0,1,0,21],["SWSE1000-42EM0",1,0,1,14],["SWSE1000-42EX0",1,0,0,14]],"accessori":[["KM-01","Stainless steel pole mounting kit for SWA/SWS/HWA/HWS enclosures, poles up to 2\" (50 mm)",24],["KM-02","Universal stainless steel wall mounting kit for SWA/SWS/HWA/HWS enclosures",24]],"opzioni":[["Codes","Codes built from datasheet B00037-00: to be confirmed in the quotation"]],"fonte":"manufacturer configurator and datasheets (October 2026)","sprite":{"url":"https://cdn.prod.website-files.com/6aa55eca30c5bd4a1e486a4c/6ad9046fb5b3225595fa62f0_solexy-varianti-sprite.jpg","colonne":10,"lato":200}}