Gas flow meter based on the fluidic oscillation principle, with no moving parts and minimal pressure loss. The latest version is suitable for both dry and wet gases and allows natural condensate drainage. The instrument provides a pulse output and a digital display with flow rate and totaliser, and is available in an ATEX/IECEx version.

Features

  • Ranges from 0.12…12 Nm³/h up to 60…6000 Nm³/h (air)
  • Flanged connections DN25…200, ANSI 1"…8"
  • Stainless steel body
  • Maximum pressure 16 bar, maximum temperature 120 °C (60 °C for Ex version)
  • Tolerance ±1.5 % of reading (air)
  • Pulse output, digital display for flow rate and totaliser
  • Configurable electronics with calibration software and connection adapter

Operating principle

An orifice in the pipe diverts a constant proportion of the gas into a bypass containing the oscillating cell. There the flow meets a deflector and, owing to the alternating pressures generated in the connecting channel, continually changes direction: the gas column oscillates at a frequency proportional to the velocity and hence to the volumetric flow, which is picked up by a sensor.

Applications

Industrial processes, biogas plants, wastewater treatment plants and volume measurement of hydrogen and other gases.

Zone 1
Explosive gas atmosphere likely to occur in normal operation
Zone 2
Explosive gas atmosphere unlikely to occur and, if it does, only for a short period
# General Type: Fluidic oscillation flow meter for gases Medium: dry and wet gases Tolerance: ±1.5 % of reading (air) # Process data Measuring range: from 0.12…12 Nm³/h to 60…6000 Nm³/h (air) Max. pressure: 16 bar Max. temperature: 120 °C (Ex version: 60 °C) # Connections and materials Connections: flanged DN25…200, ANSI 1"…8" Material: stainless steel # Signals and outputs Output: pulse Display: digital, flow rate and totaliser # Ex protection Ex certifications: ATEX, IECEx