Services
Tools
Products
>
PCs and remote monitors
>
VisuNet GXP – Modular remote monitors and PCs for Zone 1/21 and 2/22
PCs and remote monitors
display-pc-remote-monitor
Pepperl+Fuchs

VisuNet GXP – Modular remote monitors and PCs for Zone 1/21 and 2/22

RM-GXP1100 · PC-GXP1100 · RM-GXP1200 · PC-GXP1200

Pepperl+Fuchs VisuNet GXP operator stations for Zone 1/21 and 2/22: stainless steel thin clients or PCs, 21.5" Full HD or 19" display, field-replaceable modules, designed for pharma and chemicals.

ATEX
IECEx
CE
Description
Technical Specifications
Applications
Download
Datasheets

VisuNet GXP is the modular Pepperl+Fuchs HMI platform for installing monitors and PCs directly in Zone 1/21 or 2/22. It consists of three modules – display unit, power supply unit and computing unit – that are assembled and replaced in the field, reducing maintenance time. The computing unit is available as a Remote Monitor (thin client with VisuNet RM Shell or IGEL OS firmware, for access to virtualised control systems or remote workstations) or as a PC with Windows 10 IoT, on which you can install your own SCADA software.

The gap-free stainless steel housing withstands the cleaning agents used in life sciences and meets GMP requirements; the glass front makes cleaning easy. At under 25 kg it is one of the lightest solutions for Zone 1/21 and can be installed without heavy pedestals, or flush-mounted in machines and cabinet doors.

Key features

  • 21.5" Full HD 16:9 or 19" SXGA display, antiglare safety glass and 10-point capacitive multitouch usable with gloves
  • 18-36 V DC or 115/230 V AC power supply
  • 1000BASE-T Ex e Ethernet or single-mode/multimode optically intrinsically safe fibre optics
  • Optional RS232/RS485 Ex e modules, Ex i interfaces for IDM scanners and peripherals, Bluetooth and LEGIC RFID reader
  • Pedestal, arm, wall or panel mounting (bezel or flush mounting)

In Variants and codes choose the model and complete the order code with the options: the configurator follows the Pepperl+Fuchs price list combinations and disables incompatible ones. “Request a quote” sends us the complete code, which we check with Pepperl+Fuchs before quoting.

Zone 1
Explosive gas atmosphere likely to occur in normal operation
Zone 2
Explosive gas atmosphere unlikely to occur and, if it does, only for a short period
Zone 21
Explosive dust atmosphere likely to occur in normal operation
Zone 22
Explosive dust atmosphere unlikely to occur and, if it does, only for a short period
# General Product type: Remote monitor (thin client) or PC for hazardous areas Brand: Pepperl+Fuchs Series: VisuNet GXP Modules: display unit, power supply unit, computing unit (field-replaceable) Display: 21.5" Full HD 16:9 or 19" SXGA 5:4 Touch: 10-point projected capacitive multitouch (optional) Software: VisuNet RM Shell 6, IGEL OS 11/12 or Windows 10 IoT Enterprise # Certifications Protection: ATEX/IECEx Zone 1/21 or Zone 2/22 (by model) Certifications: ATEX, IECEx, CE # Electrical Power supply: 18-36 V DC or 115/230 V AC, 50-60 Hz Network interfaces: 1000BASE-T Ex e, 1000BASE-SX multimode or 1000BASE-LX single-mode fibre optics USB: 1x USB Ex e, 2x USB Ex i Optional modules: RS232 Ex e, RS485 Ex e, LAN Ex e, Ex i IDM scanner interfaces, Ex i RS232 # Mechanical Housing: stainless steel, gap-free GMP design Mounting: pedestal, arm, wall, panel or flush Weight: under 25 kg # Ambient Operating temperature: up to -20 … +50 °C (by configuration)
{"v":1,"colonne":[{"nome":"Type","valori":["Remote Monitor","PC"]},{"nome":"Zone","valori":["Zone 2/22","Zone 1/21"]}],"righe":[["RM-GXP1200",0,0],["PC-GXP1200",1,0],["RM-GXP1100",0,1],["PC-GXP1100",1,1]],"descrizioni":["GXP Remote Monitor System; Zone 2/22","GXP Personal Computer System; Zone 2/22","GXP Remote Monitor System; Zone 1/21","GXP Personal Computer System; Zone 1/21"],"suffissi":[{"nome":"Display Unit","valori":[["21.5\" (16:9), Full HD (1920x1080 pixel)","-22F",{},[]],["19\", SXGA (1280x1024 pixel)","-19S",{},[]]],"obbl":true,"certo":true,"std":"— select —"},{"nome":"Front Glass & Touch","valori":[["Antiglare Security Glass, No touch","N",{},[]],["Antiglare Security Glass, Projective Capacitive 10 Finger Multitouch","C",{},[]]],"obbl":true,"certo":true,"std":"— select —"},{"nome":"Bluetooth and RFID","valori":[["Standard","1",{},[]],["Bluetooth Interface (Not supported with IGEL OS)","2",{},[]],["Bluetooth Interface & RFID Reader (w/ LEGIC support) (Not supported with IGEL OS)","3",{},["#0:1"]]],"obbl":true,"certo":true,"std":"— select —"},{"nome":"Power Supply Unit","valori":[["18-36 V DC","-D",{},[]],["115 / 230 V AC, 50-60 Hz","-A",{},[]]],"obbl":true,"certo":true,"std":"— select —"},{"nome":"Network interfaces","valori":[["1x 1000BASE-T LAN Ex e, 1x USB Ex e, 2x USB Ex i","-E",{},[]],["1x 1000BASE-SX Multi-Mode Fibre Optic Ex, 1x USB Ex e, 2x USB Ex i","-S",{},[]],["1x 1000BASE-LX Single-Mode Fibre Optic Ex, 1x USB Ex e, 2x USB Ex i","-L",{},[]]],"obbl":true,"certo":true,"std":"— select —"},{"nome":"Module A","valori":[["No additional interface module","N",{},[]],["1x TTY Ex i for Barcode Reader (PSCAN-D) and Base station (PSCAN-B) [for replacement only]","B",{},[]],["1x 1000BASE-T LAN Ex e","E",{},[]],["1x RS232 Ex e","1",{},[]],["1x RS485 Ex e","2",{},[]],["1x Ex i Scanner interface IDM (1D wired & Base station)","3",{},[]],["1x Ex i Scanner interface IDM (2D wired)","4",{},[]],["1x Ex i RS232 interface for peripheral devices (e.g. MT weighing scale)","5",{},[]]],"obbl":true,"certo":true,"std":"— select —"},{"nome":"Module B","valori":[["No additional interface module","N",{},[]],["1x TTY Ex i for Barcode Reader (PSCAN-D) and Base station (PSCAN-B) [for replacement only]","B",{},["#5:0","#5:1","#5:2","#5:3","#5:4","#5:5","#5:6","#5:7"]],["1x 1000BASE-T LAN Ex e","E",{},["#5:0","#5:3","#5:4","#5:5","#5:6","#5:7"]],["1x RS232 Ex e","1",{},["#5:0","#5:4","#5:5","#5:6","#5:7"]],["1x RS485 Ex e","2",{},["#5:0","#5:5","#5:6","#5:7"]],["1x Ex i Scanner interface IDM (1D wired & Base station)","3",{},["#5:0","#5:5","#5:6","#5:7"]],["1x Ex i Scanner interface IDM (2D wired)","4",{},["#5:0","#5:6","#5:7"]],["1x Ex i RS232 interface for peripheral devices (e.g. MT weighing scale)","5",{},["#5:0"]]],"obbl":true,"certo":true,"std":"— select —"},{"nome":"Computing Platform","valori":[["Intel® Atom Apollo Lake E39x0, 4 GB RAM, 32 GB SSD, P+F RM Shell 5.x (based on Win 10 IoT 2019 LTSC)","T3",{"0":[1]},[]],["Intel® Atom Elkhart Lake x6211E, 4 GB RAM, 64 GB SSD, RM Shell 6 (based on Win 10 IoT Enterprise LTSC 2021 x64)","T4",{"0":[1]},[]],["Intel® Atom Elkhart Lake x6211E, 4 GB RAM, 64 GB SSD, IGEL OS 11 (based on Linux, without licence)","TI",{"0":[1]},["#2:1"]],["Intel® Atom Elkhart Lake x6211E, 4 GB RAM, 64 GB SSD, IGEL OS 12 (based on Linux, without licence)","TJ",{"0":[1]},["#2:1"]],["Intel® Atom Bay Trail E3845, 4 GB RAM, 128 GB SSD, Windows 10 IoT Enterprise LTSB x64","P2",{"0":[0]},[]],["Intel® Atom Apollo Lake E3940, 8 GB RAM, 240 GB SSD, Windows 10 IoT Enterprise LTSC 2019 x64","P3",{"0":[0]},[]],["Intel® Atom Apollo Lake E3940, 8 GB RAM, 480 GB SSD, Windows 10 IoT Enterprise LTSC 2019 x64","P4",{"0":[0]},[]],["Intel® Atom Elkhart Lake x6425RE, 8 GB RAM, 240 GB SSD, Windows 10 IoT Enterprise LTSC 2021 x64","P5",{"0":[0]},[]],["Intel® Atom Elkhart Lake x6425RE, 8 GB RAM, 480 GB SSD, Windows 10 IoT Enterprise LTSC 2021 x64","P6",{"0":[0]},[]]],"obbl":true,"certo":true,"std":"— select —"},{"nome":"Housing","valori":[["No bezel, prepared for flush mounting (OEM Option - please contact local SEC)","-NN-N0",{},[]],["Bezel; prepared for panel mounting or into Housing AG-XX00 (21.5\" Display unit only)","-S1-N0",{},["#0:1"]],["Bezel; prepared for panel mounting or into Housing AG1 (19\" Display unit only)","-S2-N0",{},["#0:0"]],["EX1 Housing AG1, Front opening for Pedestal/Ceiling/Wall-Arm (19\" Display unit only)","-H2-N0",{},["#0:0"]],["EX1 Housing AG1, Rear opening, for Basic line pedestal only [19\" Display unit only]","-H3-N0",{},["#0:0"]],["GXP Housing AG-XX00, Front Opening / New Hinge Mech, 1.6µm Bead Blasted Finish (21.5\" Display unit only)","-H4-N0",{},["#0:1"]]],"obbl":true,"certo":true,"std":"— select —"}],"suffissiTitolo":"Configure the order code","accessori":[["DPU1100-…","GXP replacement display unit Zone 1/21, configurable (size, touch, interfaces, bezel)"],["DPU1200-…","GXP replacement display unit Zone 2/22, configurable"],["PSU1100-…","GXP replacement power supply unit Zone 1/21, 18-36 V DC or 115/230 V AC"],["PSU1200-…","GXP replacement power supply unit Zone 2/22, 18-36 V DC or 115/230 V AC"],["TCU1100-… / TCU1200-…","GXP replacement thin client unit Zone 1/21 or 2/22, configurable (interfaces, modules, firmware)"],["PCU1100-… / PCU1200-…","GXP replacement PC unit Zone 1/21 or 2/22, configurable (interfaces, modules, platform)"],["WALL-BRACKET-XX00-3-304-N0","Wall Mount Bracket"],["PEDESTAL-XX00-124-3-304-TRN-N0","Pedestal, Swivel"],["KIT-PM-XX00-22F-304-N0","Panel Mount Kit for 21.5\" GXP"],["SCANNER-HOLDER-U1-XX00-N0","Scanner Holder for IDM, Ident-Ex, PSCAN for AG-XX00"],["HOLDER-BRACKET-XX00-IDMx61-B-N","Mounting Bracket for IDMx61 Base Station for AG-XX00"],["DATL-IDM-DB-S-XX00-N0","IDM Scanner Connection Cable inside AG-XX00"],["DATL-PSCAN-D-XX00-N0","PSCAN Scanner Connector Cable inside AG-XX00"],["AG-XX00-22F-304A-NN-N0","GXP 21.5\" AG-XX00 \"H1\" Replacement Housing"],["AG-XX00-22F-304A-HS-N0","GXP 21.5\" AG-XX00 \"H4\" Replacement Housing (2020+ Display Units)"],["WALL-BRACKET5","Wall Mount Bracket"],["PEDESTAL5-1458-TURN","Pedestal, Swivel"],["PEDESTAL5-1458-FIX","Pedestal, Fixed"],["SCANNER-HOLDER-U1-AG1-N0","Scanner Holder for IDM, Ident-Ex, PSCAN for AG1"],["AG1-19S-304A-NN-NN-N0","GXP 19\" AG1 Replacement Housing"],["HOLDER-BRACKET-AG1-IDMx61-B-N0","Bracket to mount IDMx61-B-J1-BT-N0 Base Station to AG1 housing"],["PS1000-A6-24.5","PS1000 - 24VDC, 5A Power Supply, Universal Input"],["1002MC-SX","Multimode Gigabit Media Converter"],["1002MC-LX-10","Single mode Gigabit Media Converter"],["DATL-FO-SM-LC-SC-15","FO Breakout Cable, Singlemode, LC to SC"],["DATL-FO-MM-LC-SC-15","FO Breakout Cable, Multimode, LC to SC"],["DATL-FO-SM-LC-LC-15","FO Breakout Cable, Singlemode, LC to LC"],["DATL-FO-MM-LC-LC-15","FO Breakout Cable, Multimode, LC to LC"],["DKX4-101","Raritan KVM Over IP Extender - Requires RM Shell Pro Licence"]],"datasheet":{"base":"https://files.pepperl-fuchs.com/webcat/navi/productInfo/pds/","pn":["","","",""],"apn":["","","","","","","","","","548267","548396","548376","","","","","","","548268","","548395","70103517","","","548310","","","548313","70118493"],"noit":["548267","548268","548310","548313","548376","548395","548396","70103517","70118493"]},"fonte":"Pepperl+Fuchs VisuNet HMI Price List 2026 (EDM 14-5879C)"}
No items found.
Oil & Gas
Oil & Gas
Chemical and petrochemical
Chemical and petrochemical
Pharmaceutical
Pharmaceutical
VisuNet GXP – Modular remote monitors and PCs for Zone 1/21 and 2/22