Services
Tools
Products
>
Cable glands for unarmoured cable
>
CG.EM EMC metal cable glands – for shielded cables, Ex d / Ex e / Ex t
Cable glands for unarmoured cable
cablaggio-pressacavi-cavo-non-armato
Pepperl+Fuchs

CG.EM EMC metal cable glands – for shielded cables, Ex d / Ex e / Ex t

CG.EM · M16…M50 · NPT 3/8"…1-1/2" · BN / SS

CG.EM metal cable glands for shielded cables, with an EMC spring insert for connecting the shield, in nickel-plated brass or AISI 316 stainless steel, M16–M50 or NPT 3/8"–1-1/2" threads, ATEX/IECEx certified Ex db, Ex eb and Ex tb.

ATEX
IECEx
UL
CCC
CE
Description
Technical Specifications
Applications
Download
Datasheets

CG.EM cable glands are the shielded-cable version of the CG.NA series: the cable shield is placed in the internal EMC spring insert, which provides the earth connection needed for electromagnetic compatibility, while the seal inserts seal the outer sheath.

They share the CG.NA certificates and type code structure: type, thread and size, body material (BN/SS), seals (C chloroprene, S silicone), thread length in mm and pack. Version CG.EM.M20.BN.S.9 is listed as Ex e in the price list.

Key features

  • EMC spring insert and pressure ring for contact with the shield
  • M16…M50 metric and NPT 3/8"…1-1/2" threads
  • Clamping range 4 to 35 mm with S1/S2/S3 seal insert combinations
  • Body in nickel-plated brass or AISI 316 stainless steel
  • IP66/IP68, UL Type 4X; chloroprene seals −40…+80 °C or silicone seals
  • ATEX IMQ 14 ATEX 012X, IECEx IMQ 14.0004X and CCC certificates
  • cULus (UL 2225) for sizes from M20 / NPT 1/2" upwards

Use the filters in Variants and codes to find the exact part number: where available you will find the official Pepperl+Fuchs datasheet and, for every code, a quote request. For versions not listed, accessories or availability, contact us.

Zone 1
Explosive gas atmosphere likely to occur in normal operation
Zone 2
Explosive gas atmosphere unlikely to occur and, if it does, only for a short period
Zone 21
Explosive dust atmosphere likely to occur in normal operation
Zone 22
Explosive dust atmosphere unlikely to occur and, if it does, only for a short period
# General Product type: EMC metal cable gland for shielded cables Brand: Pepperl+Fuchs Series: CG.EM Threads: M16…M50 (ISO 1.5 mm pitch); NPT 3/8"…1-1/2" (ANSI/ASME B1.20.1) Body material: Nickel-plated brass or AISI 316 stainless steel (1.4401) # Certifications ATEX: IMQ 14 ATEX 012X – II 2 GD Ex db IIC Gb / Ex eb IIC Gb / Ex tb IIIC Db IECEx: IECEx IMQ 14.0004X CCC: 2021312313000344 UL: cULus E490962 (UL 2225) – depending on size # Mechanical Clamping range: 4…35 mm depending on size Seals: Chloroprene/neoprene or silicone Degree of protection: IP66 / IP68, UL Type 4X Ambient temperature: Chloroprene −40…+80 °C; silicone down to −60 °C
{"v":1,"colonne":[{"nome":"Size","valori":["M16","M20","M25","M32","M40","M50","NPT3/8","NPT1/2","NPT3/4","NPT1","NPT1-1/4","NPT1-1/2"]},{"nome":"Cable Ø mm","valori":["4–8","4–12","10–18","14–24","22–32","26–35"]},{"nome":"Material · seals","valori":["Brass Ni · CR","Brass Ni · silicone","SS 316 · CR"]},{"nome":"Thread length","valori":["9 mm","16 mm","18 mm","19 mm","20 mm"]},{"nome":"Pack","valori":["Unpacked","1 pcs","5 pcs","15 pcs","25 pcs","50 pcs"]}],"righe":[["CG.EM.M16.BN.C.16",0,0,0,1,0],["CG.EM.M16.BN.C.16.K01",0,0,0,1,1],["CG.EM.M16.BN.C.16.K50",0,0,0,1,5],["CG.EM.M16.BN.S.16.K01",0,0,1,1,1],["CG.EM.M16.SS.C.16",0,0,2,1,0],["CG.EM.M16.SS.C.16.K01",0,0,2,1,1],["CG.EM.M16.SS.C.16.K50",0,0,2,1,5],["CG.EM.M20.BN.C.18",1,1,0,2,0],["CG.EM.M20.BN.C.18.K01",1,1,0,2,1],["CG.EM.M20.BN.C.18.K50",1,1,0,2,5],["CG.EM.M20.BN.S.9.K50",1,1,1,0,5],["CG.EM.M20.BN.S.18.K01",1,1,1,2,1],["CG.EM.M20.BN.S.18.K50",1,1,1,2,5],["CG.EM.M20.SS.C.18",1,1,2,2,0],["CG.EM.M20.SS.C.18.K01",1,1,2,2,1],["CG.EM.M20.SS.C.18.K50",1,1,2,2,5],["CG.EM.M25.BN.C.16",2,2,0,1,0],["CG.EM.M25.BN.C.16.K01",2,2,0,1,1],["CG.EM.M25.BN.C.16.K25",2,2,0,1,4],["CG.EM.M25.SS.C.16",2,2,2,1,0],["CG.EM.M25.SS.C.16.K01",2,2,2,1,1],["CG.EM.M25.SS.C.16.K25",2,2,2,1,4],["CG.EM.M32.BN.C.19",3,3,0,3,0],["CG.EM.M32.BN.C.19.K01",3,3,0,3,1],["CG.EM.M32.BN.C.19.K15",3,3,0,3,3],["CG.EM.M32.SS.C.19",3,3,2,3,0],["CG.EM.M32.SS.C.19.K01",3,3,2,3,1],["CG.EM.M32.SS.C.19.K15",3,3,2,3,3],["CG.EM.M40.BN.C.20",4,4,0,4,0],["CG.EM.M40.BN.C.20.K01",4,4,0,4,1],["CG.EM.M40.BN.C.20.K05",4,4,0,4,2],["CG.EM.M40.SS.C.20",4,4,2,4,0],["CG.EM.M40.SS.C.20.K01",4,4,2,4,1],["CG.EM.M40.SS.C.20.K05",4,4,2,4,2],["CG.EM.M50.BN.C.20",5,5,0,4,0],["CG.EM.M50.BN.C.20.K01",5,5,0,4,1],["CG.EM.M50.BN.C.20.K05",5,5,0,4,2],["CG.EM.M50.SS.C.20",5,5,2,4,0],["CG.EM.M50.SS.C.20.K01",5,5,2,4,1],["CG.EM.M50.SS.C.20.K05",5,5,2,4,2],["CG.EM.NPT3/8.BN.C.16",6,0,0,1,0],["CG.EM.NPT3/8.BN.C.16.K01",6,0,0,1,1],["CG.EM.NPT3/8.BN.C.16.K50",6,0,0,1,5],["CG.EM.NPT3/8.SS.C.16",6,0,2,1,0],["CG.EM.NPT3/8.SS.C.16.K01",6,0,2,1,1],["CG.EM.NPT3/8.SS.C.16.K50",6,0,2,1,5],["CG.EM.NPT1/2.BN.C.18",7,1,0,2,0],["CG.EM.NPT1/2.BN.C.18.K01",7,1,0,2,1],["CG.EM.NPT1/2.BN.C.18.K50",7,1,0,2,5],["CG.EM.NPT1/2.SS.C.18",7,1,2,2,0],["CG.EM.NPT1/2.SS.C.18.K01",7,1,2,2,1],["CG.EM.NPT1/2.SS.C.18.K50",7,1,2,2,5],["CG.EM.NPT3/4.BN.C.16",8,2,0,1,0],["CG.EM.NPT3/4.BN.C.16.K01",8,2,0,1,1],["CG.EM.NPT3/4.BN.C.16.K25",8,2,0,1,4],["CG.EM.NPT3/4.SS.C.16",8,2,2,1,0],["CG.EM.NPT3/4.SS.C.16.K01",8,2,2,1,1],["CG.EM.NPT3/4.SS.C.16.K25",8,2,2,1,4],["CG.EM.NPT1.BN.C.20",9,3,0,4,0],["CG.EM.NPT1.BN.C.20.K01",9,3,0,4,1],["CG.EM.NPT1.BN.C.20.K15",9,3,0,4,3],["CG.EM.NPT1.SS.C.20",9,3,2,4,0],["CG.EM.NPT1.SS.C.20.K01",9,3,2,4,1],["CG.EM.NPT1.SS.C.20.K15",9,3,2,4,3],["CG.EM.NPT1-1/4.BN.C.20",10,4,0,4,0],["CG.EM.NPT1-1/4.BN.C.20.K01",10,4,0,4,1],["CG.EM.NPT1-1/4.BN.C.20.K05",10,4,0,4,2],["CG.EM.NPT1-1/4.SS.C.20",10,4,2,4,0],["CG.EM.NPT1-1/4.SS.C.20.K01",10,4,2,4,1],["CG.EM.NPT1-1/4.SS.C.20.K05",10,4,2,4,2],["CG.EM.NPT1-1/2.BN.C.20",11,5,0,4,0],["CG.EM.NPT1-1/2.BN.C.20.K01",11,5,0,4,1],["CG.EM.NPT1-1/2.BN.C.20.K05",11,5,0,4,2],["CG.EM.NPT1-1/2.SS.C.20",11,5,2,4,0],["CG.EM.NPT1-1/2.SS.C.20.K01",11,5,2,4,1],["CG.EM.NPT1-1/2.SS.C.20.K05",11,5,2,4,2]],"fonte":"Pepperl+Fuchs price list 2026 / official documentation"}
No items found.
Oil & Gas
Oil & Gas
Chemical and petrochemical
Chemical and petrochemical
Pharmaceutical
Pharmaceutical
CG.EM EMC metal cable glands – for shielded cables, Ex d / Ex e / Ex t