K-System – Isolated barriers for analogue outputs and SMART current drivers
Isolated barriers
sicurezza-barriere-isolate
Pepperl+Fuchs

K-System – Isolated barriers for analogue outputs and SMART current drivers

KCD2-SCD-Ex1 · KFD2-SCD2-Ex1.LK · KFD0-SCS-Ex1.55…

K-System isolated barriers for driving positioners, I/P converters and valves in the hazardous area with a 4–20 mA signal: SMART current drivers with HART, line fault detection (LFD) and versions up to SIL 3.

ATEX
UL
IECEx
SIL
CE
Description
Technical Specifications
Applications
Download
Datasheets

These isolated barriers carry the 4–20 mA signal from the control system to SMART I/P converters, electrical valves and positioners installed in the hazardous area, keeping the two circuits galvanically isolated. HART digital signals superimposed on the analogue value are transferred bidirectionally, so field instruments can be configured and diagnosed from the control system.

Alongside the Power Rail supplied current drivers, loop-powered versions with only a 5 V voltage drop and low power dissipation are available, plus a current/voltage converter that turns a 0–20 mA or 0–10 V signal from the hazardous area into a 4–20 mA output in the safe area.

Key features

  • Current output to the field with loads up to 650 Ω (KFD2-SCD2)
  • Bidirectional HART transfer and HART communicator test sockets
  • Line fault detection (LFD): an open or shorted field circuit presents a high impedance to the control side
  • Fault indication via LEDs and a collective error message output
  • Loop-powered version with a 5 V drop, also suitable for solenoid valves and LEDs
  • 0.1 % accuracy and versions up to SIL 3 to IEC/EN 61508
  • 12.5 mm or 20 mm width, screw, removable screw or push-in spring terminals

Use the filters in Variants and codes to find the exact part number: where available you will find the official Pepperl+Fuchs datasheet and, for every code, a quote request. For versions not listed, accessories or availability, contact us.

Zone 0
Explosive gas atmosphere present continuously or for long periods
Zone 1
Explosive gas atmosphere likely to occur in normal operation
Zone 2
Explosive gas atmosphere unlikely to occur and, if it does, only for a short period
Zone 20
Explosive dust atmosphere present continuously or for long periods
Zone 21
Explosive dust atmosphere likely to occur in normal operation
Zone 22
Explosive dust atmosphere unlikely to occur and, if it does, only for a short period
# General Product type: Intrinsically safe isolated barrier for analogue outputs Brand: Pepperl+Fuchs Series: K-System Functions: SMART current driver, SMART current driver/repeater, current/voltage converter Channels: 1 or 2 Field loads: I/P converters, electrical valves, positioners # Certifications Type of protection: intrinsic safety, associated apparatus Field circuits: Zone 0, 1, 2 (Div. 1, 2); KFD0-SCS-Ex1.55: Zone 1, 2 Functional safety: up to SIL 3 (IEC/EN 61508) Electromagnetic compatibility: Directive 2014/30/EU # Electrical Supply: 24 V DC (Power Rail) or loop powered Rated voltage: 19–30 V DC (KFD2-SCD2); 12–35 V DC loop powered (KFD0-CC) Input signal: 4–20 mA from the control system; 0–20 mA or 0–10 V from the field (KFD0-CC) Output: 4–20 mA, load up to 650 Ω (KFD2-SCD2) Voltage drop: 5 V (KFD0-SCS-Ex1.55) Accuracy: 0.1 % Diagnostics: line fault detection (LFD) # Mechanical Width: 12.5 mm or 20 mm Terminals: screw, removable screw or push-in spring Settings: DIP switches and potentiometers (KFD0-CC)
{"v":1,"colonne":[{"nome":"Function","valori":["Current/Voltage Converter","SMART Current Driver","SMART Current Driver/Repeater"]},{"nome":"Channels","valori":["1","2"]},{"nome":"Supply","valori":["24 V DC (Power Rail)","Loop powered"]},{"nome":"Terminals","valori":["Removable screw","Screw","Spring"]},{"nome":"SIL","valori":["No","SIL 2","SIL 3"]}],"righe":[["KFD0-CC-EX1",0,0,1,0,0],["KFD0-SCS-EX1.55",2,0,1,0,1],["KFD2-SCD2-EX1.LK",1,0,0,0,1],["KFD2-SCD2-EX2.LK",1,1,0,0,1],["KCD2-SCD-EX1.ES.SP",1,0,0,2,2],["KCD2-SCD-EX1.ES",1,0,0,1,2],["KCD2-SCD-EX1",1,0,0,1,1],["KCD2-SCD-EX1.SP",1,0,0,2,1]],"datasheet":{"base":"https://files.pepperl-fuchs.com/webcat/navi/productInfo/pds/","pn":["043690","240495","295086","295089","324384","70101788","70150440","70150941"],"apn":[],"noit":["043690","240495","295086","295089","324384","70101788","70150440","70150941"]},"fonte":"Pepperl+Fuchs price list 2026 / official datasheets"}
No items found.
Oil & Gas
Oil & Gas
Chemical and petrochemical
Chemical and petrochemical
Pharmaceutical
Pharmaceutical
K-System – Isolated barriers for analogue outputs and SMART current drivers