Services
Tools
Products
>
Isolated barriers
>
K-System – Isolated barriers for digital outputs and solenoid drivers
Isolated barriers
sicurezza-barriere-isolate
Pepperl+Fuchs

K-System – Isolated barriers for digital outputs and solenoid drivers

KCD2-SLD-Ex1 · KCD0-SD3-Ex1 · KFD0-SD2-Ex1 · KFD2-SL2-Ex2…

K-System solenoid drivers that power solenoid valves, LEDs and audible alarms in the hazardous area, with outputs from 10 V / 100 mA to 15.3 V / 17 mA, Power Rail or loop supply, and versions up to SIL 3.

ATEX
UL
IECEx
SIL
CE
Description
Technical Specifications
Applications
Download
Datasheets

K-System solenoid drivers pass a digital command from the control system to solenoid valves, LEDs, audible alarms and similar loads installed in the hazardous area (Zone 0, 1, 2), with galvanic isolation between the circuits. The output has a resistive characteristic, so the available voltage and current depend on the load; the range therefore offers several voltage/current combinations to match the coil being driven.

In the loop-powered versions the energy for the field side is taken directly from the control signal, with no separate supply. Other models are powered via Power Rail and offer logic inputs with AND/OR functions and a service port for function testing.

Key features

  • Outputs from 10 V / 45 mA up to 13 V / 100 mA and 15.3 V / 17 mA
  • Loop powered, bus powered or 24 V DC Power Rail versions
  • 1- or 2-channel versions, 12.5 mm or 20 mm width
  • KFD2-VM-Ex1.35.L with 3 logic inputs in AND/OR configuration and front test socket
  • Versions up to SIL 3 to IEC/EN 61508
  • LED status indication
  • Screw or removable screw terminals

Use the filters in Variants and codes to find the exact part number: where available you will find the official Pepperl+Fuchs datasheet and, for every code, a quote request. For versions not listed, accessories or availability, contact us.

Zone 0
Explosive gas atmosphere present continuously or for long periods
Zone 1
Explosive gas atmosphere likely to occur in normal operation
Zone 2
Explosive gas atmosphere unlikely to occur and, if it does, only for a short period
Zone 20
Explosive dust atmosphere present continuously or for long periods
Zone 21
Explosive dust atmosphere likely to occur in normal operation
Zone 22
Explosive dust atmosphere unlikely to occur and, if it does, only for a short period
# General Product type: Intrinsically safe isolated barrier for digital outputs (solenoid driver) Brand: Pepperl+Fuchs Series: K-System Field loads: solenoid valves, LEDs, audible alarms Channels: 1 or 2 # Certifications Type of protection: intrinsic safety, associated apparatus Field circuits: Zone 0, 1, 2 (Div. 1, 2) Functional safety: up to SIL 3 (IEC/EN 61508) Electromagnetic compatibility: Directive 2014/30/EU, EN 61326-1, NAMUR NE 21 # Electrical Supply: 24 V DC (Power Rail), bus or loop powered Rated voltage: 20–35 V DC (KFD0-SD2); 20–30 V DC (KFD2-VM) Available outputs: 10 V / 45, 65 or 100 mA; 11 V / 80 mA; 11.7 V / 45 mA; 12 V / 45 mA; 13 V / 100 mA; 15.3 V / 17 mA Control input: 24 V DC signal; 3 AND/OR logic inputs (KFD2-VM) # Mechanical Width: 12.5 mm or 20 mm Terminals: screw or removable screw
{"v":1,"colonne":[{"nome":"Channels","valori":["1","2"]},{"nome":"Output","valori":["10 V / 100 mA","10 V / 45 mA","10 V / 65 mA","11 V / 80 mA","11.7 V / 45 mA","12 V / 45 mA","13 V / 100 mA","15.3 V / 17 mA"]},{"nome":"Supply","valori":["24 V DC (Power Rail)","Bus or loop powered","Loop powered"]},{"nome":"Terminals","valori":["Removable screw","Screw"]},{"nome":"SIL","valori":["No","SIL 2","SIL 3"]}],"righe":[["KFD2-VM-EX1.35.L",0,7,0,0,0],["KFD0-SD2-EX1.10100",0,0,2,0,2],["KFD0-SD2-EX1.1180",0,3,2,0,2],["KFD2-SL2-EX2.B",1,4,0,0,1],["KFD0-SD2-EX2.1045",1,1,2,0,2],["KFD0-SD2-EX2.1245",1,5,2,0,2],["KFD2-SLD-EX1.13100",0,6,0,0,2],["KCD0-SD3-EX1.1245",0,5,2,1,2],["KCD0-SD3-EX1.1045",0,1,2,1,2],["KCD2-SLD-EX1.1045",0,1,1,1,2],["KCD2-SLD-EX1.1065",0,2,1,1,2],["KCD2-SLD-EX1.1245",0,5,1,1,2],["KFD2-SL2-EX2",1,4,0,0,1]],"datasheet":{"base":"https://files.pepperl-fuchs.com/webcat/navi/productInfo/pds/","pn":["103076","133237","133239","184259","242032","242033","243753","304978","304983","70104928","70104929","70104930","70180149"],"apn":[],"noit":["103076","133237","133239","184259","242032","242033","243753","304978","304983","70104928","70104929","70104930","70180149"]},"fonte":"Pepperl+Fuchs price list 2026 / official datasheets"}