Services
Tools
Products
>
Isolated barriers
>
K-System – Isolated barriers for frequency, rotation speed and conductive level
Isolated barriers
sicurezza-barriere-isolate
Pepperl+Fuchs

K-System – Isolated barriers for frequency, rotation speed and conductive level

KFD2-UFC-Ex1.D · KFD2-UFT-Ex2.D · KFD2-DWB-Ex1.D…

K-System isolated barriers for processing pulses and levels from the hazardous area: frequency converters with trip values, speed, direction and synchronisation monitors, and conductive level electrode relays, SIL 2 versions.

ATEX
IECEx
SIL
CE
Description
Technical Specifications
Applications
Download
Datasheets

These modules receive pulses from NAMUR sensors or mechanical contacts in the hazardous area (Zone 0, 1, 2) and process them directly in the barrier: they convert frequency into a 0/4–20 mA signal, compare the value with low and high trip values, and drive relay and transistor outputs. Two-input versions detect rotational direction, slip and synchronisation between two shafts.

The range is completed by conductive switch amplifiers, which supply the AC measuring voltage to level electrodes and switch a changeover contact when the conductive liquid reaches them, with on/off or minimum/maximum control and an adjustable delay.

Key features

  • Inputs for NAMUR sensors or dry contacts, frequency from 1 mHz to 5 kHz (KFD2-UFC)
  • 0/4–20 mA analogue output proportional to frequency, relay and transistor outputs
  • Min/max trip values, pulse divider, start-up override
  • Rotational direction, slip and synchronisation monitoring with 2 inputs up to 1 kHz (KFD2-UFT)
  • Electrode relays with 1–150 kΩ adjustable sensitivity and 0.5–10 s delay
  • Configuration via front keypad or PACTware, line fault detection (LFD)
  • Versions up to SIL 2 to IEC/EN 61508 / IEC/EN 61511

Use the filters in Variants and codes to find the exact part number: where available you will find the official Pepperl+Fuchs datasheet and, for every code, a quote request. For versions not listed, accessories or availability, contact us.

Zone 0
Explosive gas atmosphere present continuously or for long periods
Zone 1
Explosive gas atmosphere likely to occur in normal operation
Zone 2
Explosive gas atmosphere unlikely to occur and, if it does, only for a short period
Zone 20
Explosive dust atmosphere present continuously or for long periods
Zone 21
Explosive dust atmosphere likely to occur in normal operation
Zone 22
Explosive dust atmosphere unlikely to occur and, if it does, only for a short period
# General Product type: Intrinsically safe isolated barrier for frequency and level signals Brand: Pepperl+Fuchs Series: K-System Functions: frequency converter with trip values, with direction and synchronisation monitor, rotation speed monitor, conductive switch amplifier Channels: 1 or 2 Configuration: front keypad, PACTware or DIP switches # Certifications Type of protection: intrinsic safety, associated apparatus Field circuits: Zone 0, 1, 2 (Div. 1, 2) Functional safety: up to SIL 2 (IEC/EN 61508 / IEC/EN 61511) # Electrical Supply: 24 V DC (Power Rail), 20–90 V DC / 48–253 V AC, 115 V AC or 230 V AC Inputs: NAMUR sensors, dry contacts, level electrodes Input frequency: 1 mHz to 5 kHz (KFD2-UFC); up to 1 kHz (KFD2-UFT) Analogue output: 0/4–20 mA Switching outputs: relay and passive transistor Electrode sensitivity: 1–150 kΩ adjustable (KF*-ER) Diagnostics: line fault detection (LFD), LEDs to NAMUR NE 44 # Mechanical Mounting: Power Rail or supply terminals
{"v":1,"colonne":[{"nome":"Function","valori":["Conductive Switch Amplifier","Frequency Converter with Direction and Synchronization Monitor","Frequency Converter with Trip Values","Rotation Speed Monitor"]},{"nome":"Channels","valori":["1","2"]},{"nome":"Supply","valori":["24 V DC (Power Rail)","115 V AC","230 V AC","Universal AC/DC"]},{"nome":"SIL","valori":["No","SIL 2"]}],"righe":[["KFA6-ER-EX1.W.LB",0,0,2,0],["KFD2-ER-EX1.W.LB",0,0,0,0],["KFD2-UFC-EX1.D",2,0,0,1],["KFU8-UFC-EX1.D",2,0,3,1],["KFD2-UFT-EX2.D",1,1,0,0],["KFU8-UFT-EX2.D",1,1,3,0],["KFD2-DWB-EX1.D",3,0,0,1],["KFA6-DWB-EX1.D",3,0,2,1],["KFA5-DWB-EX1.D",3,0,1,1]],"datasheet":{"base":"https://files.pepperl-fuchs.com/webcat/navi/productInfo/pds/","pn":["115163","217732","231194","231197","231200","231202","231203","231207","231208"],"apn":[],"noit":["115163","217732","231194","231197","231200","231202","231203","231207","231208"]},"fonte":"Pepperl+Fuchs price list 2026 / official datasheets"}
No items found.
Oil & Gas
Oil & Gas
Chemical and petrochemical
Chemical and petrochemical
Pharmaceutical
Pharmaceutical
K-System – Isolated barriers for frequency, rotation speed and conductive level