Services
Tools
Products
>
Isolated barriers
>
K-System – Isolated barriers with temperature and strain gauge converters
Isolated barriers
sicurezza-barriere-isolate
Pepperl+Fuchs

K-System – Isolated barriers with temperature and strain gauge converters

KCD2-UT2-Ex1 · KFD2-UT2-Ex1 · KFD0-TR-Ex1 · KFD2-WAC2-Ex1.D…

K-System isolated barriers converting RTD, thermocouple, potentiometer and strain gauge signals from the hazardous area into 0/4–20 mA, with sensor breakage detection, alarm trip values and SIL 2 versions.

ATEX
UL
IECEx
SIL
CE
Description
Technical Specifications
Applications
Download
Datasheets

K-System converters receive the signal from temperature and measuring sensors installed in the hazardous area (Zone 0, 1, 2) and return it to the safe area as an isolated 0/4–20 mA signal. The range covers loop-powered Pt100 RTD converters, thermocouple converters with internal cold junction compensation, universal converters configurable with PACTware, potentiometer converters, temperature converters with trip values, and converters for strain gauges and load cells.

The universal versions accept RTDs, thermocouples, potentiometers or voltage signals and are configured from a PC; the strain gauge converter supplies up to four 350 Ω strain gauges in parallel and provides two relay outputs and an RS-485 interface.

Key features

  • Inputs for RTDs (Pt10 to Pt1000, Cu, Ni100), type E, J, K, N, R, S, T thermocouples, potentiometers and voltage
  • 0/4–20 mA output, sink or source mode on universal converters
  • Selectable temperature linearisation and DIP switch ranges (KFD0-TR)
  • Sensor breakage and line fault detection (LFD)
  • Configuration via PACTware or front keypad
  • Full or half bridge strain gauge converter with 2 relay outputs and RS-485 interface
  • Versions up to SIL 2 to IEC/EN 61508 / IEC/EN 61511

Use the filters in Variants and codes to find the exact part number: where available you will find the official Pepperl+Fuchs datasheet and, for every code, a quote request. For versions not listed, accessories or availability, contact us.

Zone 0
Explosive gas atmosphere present continuously or for long periods
Zone 1
Explosive gas atmosphere likely to occur in normal operation
Zone 2
Explosive gas atmosphere unlikely to occur and, if it does, only for a short period
Zone 20
Explosive dust atmosphere present continuously or for long periods
Zone 21
Explosive dust atmosphere likely to occur in normal operation
Zone 22
Explosive dust atmosphere unlikely to occur and, if it does, only for a short period
# General Product type: Intrinsically safe isolated barrier with signal converter Brand: Pepperl+Fuchs Series: K-System Functions: RTD, thermocouple, universal, potentiometer, trip value and strain gauge converters Channels: 1 or 2 Configuration: DIP switches and potentiometers, keypad or PACTware # Certifications Type of protection: intrinsic safety, associated apparatus Field circuits: Zone 0, 1, 2 (Div. 1, 2) Functional safety: up to SIL 2 (IEC/EN 61508 / IEC/EN 61511) # Electrical Supply: 24 V DC (Power Rail), 20–90 V DC / 48–253 V AC or loop powered RTD input: Pt10 to Pt1000, Pt GOST, Cu10/50/100, Ni100; 2- or 3-wire Pt100 (KFD0-TR) Thermocouple input: types E, J, K, N, R, S, T Other inputs: potentiometer, voltage, full or half bridge strain gauges Output: 0/4–20 mA; 0 to ±20 mA or 0 to ±10 V (KFD2-WAC2) Additional outputs: 2 relays and RS-485 interface (KFD2-WAC2) Accuracy: 0.1 % of full scale (KFD0-TR, KFD0-TT) # Mechanical Width: 12.5 mm or 20 mm Terminals: screw or removable screw Cold junction compensation: internal or via KC-CJC-** terminal block (KCD2-UT2)
{"v":1,"colonne":[{"nome":"Function","valori":["Potentiometer Converter","RTD Converter","Strain Gauge Converter","Temperature Converter with Trip Values","Thermocouple Converter","Universal Temperature Converter"]},{"nome":"Channels","valori":["1","2"]},{"nome":"Supply","valori":["24 V DC (Power Rail)","Loop powered","Universal AC/DC"]},{"nome":"Terminals","valori":["Removable screw","Screw"]},{"nome":"SIL","valori":["No","SIL 2"]}],"righe":[["KFD0-TR-EX1",1,0,1,0,0],["KFD0-TT-EX1",4,0,1,0,0],["KCD2-UT2-EX1",5,0,0,1,1],["KFD2-WAC2-EX1.D",2,0,0,0,0],["KFD2-GUT-EX1.D",3,0,0,0,1],["KFU8-GUT-EX1.D",3,0,2,0,1],["KFD2-UT2-EX2",5,1,0,0,1],["KFD2-UT2-EX2-1",5,1,0,0,1],["KFD2-UT2-EX1",5,0,0,0,1],["KFD2-PT2-EX1",0,0,0,0,0],["KFD2-PT2-EX1-1",0,0,0,0,0],["KFD2-PT2-EX1-5",0,0,0,0,0]],"datasheet":{"base":"https://files.pepperl-fuchs.com/webcat/navi/productInfo/pds/","pn":["043691","043692","225696","231221","231225","231229","248767","248768","70157025","70177748","70177760","70177763"],"apn":[],"noit":["043691","043692","225696","231221","231225","231229","248767","248768","70157025","70177748","70177760","70177763"]},"fonte":"Pepperl+Fuchs price list 2026 / official datasheets"}
No items found.
Oil & Gas
Oil & Gas
Chemical and petrochemical
Chemical and petrochemical
Pharmaceutical
Pharmaceutical