Pre-wired Pepperl+Fuchs FieldConnex junction boxes with an 8-input temperature interface (F.TI0) or a 12-channel discrete multi-input/output (F.MIO) for FOUNDATION Fieldbus H1 or PROFIBUS PA, for installation in Zone 1 or Zone 2 with sensors down to Zone 0.

ATEX
IECEx
Description
Technical Specifications
Applications
Download
Datasheets

These junction boxes bring conventional field signals onto the fieldbus. The F.TI0 versions house the RD0-TI-Ex8 interface with 8 inputs for RTDs, thermocouples and resistance or millivolt signals; the F.MIO versions house the R8D0-MIO-Ex12 multi-input/output for discrete inputs and solenoid valves. The series also includes some FieldBarrier, Segment Protector, passive and engineered junction boxes.

The type code gives: enclosure (P polyester GRP, S electropolished 316 stainless steel, T brushed 316L stainless steel), certification and installation zone (A/G Zone 1, B/H Zone 2; G and H also IECEx) with number of channels, bus type (F FOUNDATION Fieldbus H1, P PROFIBUS PA), terminals, bus and field line entries, tag plate and grounding bar.

Key features

  • F.TI0: 8 temperature inputs; F.MIO: 12 channels for discrete inputs and valves
  • Installation in Zone 1 with sensors and actuators in Zone 0, or in Zone 2
  • F.TI0 Zone 1: II 2(1)G Ex ia [ia Ga] IIC T4 Gb; F.MIO Zone 1: II 2(1)G Ex ib [ia Ga] IIC T4 Gb
  • Certificates PTB 07 ATEX 1061 X (Zone 1) and PTB 17 ATEX 1011 X (Zone 2)
  • Polyester GRP or 316L stainless steel enclosures, degree of protection IP66
  • M20 entries with polyamide, nickel-plated brass or stainless steel cable glands, also for armoured cable, or stopping plugs

Use the filters in Variants and codes to find the exact part number: where available you will find the official Pepperl+Fuchs datasheet and, for every code, a quote request. For versions not listed, accessories or availability, contact us.

Zone 0
Explosive gas atmosphere present continuously or for long periods
Zone 1
Explosive gas atmosphere likely to occur in normal operation
Zone 2
Explosive gas atmosphere unlikely to occur and, if it does, only for a short period
Zone 20
Explosive dust atmosphere present continuously or for long periods
Zone 21
Explosive dust atmosphere likely to occur in normal operation
Zone 22
Explosive dust atmosphere unlikely to occur and, if it does, only for a short period
# General Product type: Fieldbus junction box with remote I/O Brand: Pepperl+Fuchs Series: FieldConnex F.TI0 · F.MIO Installed components: RD0-TI-Ex8 (F.TI0), R8D0-MIO-Ex12 (F.MIO) Fieldbus: FOUNDATION Fieldbus H1, PROFIBUS PA Channels: 8 temperature inputs (F.TI0), 12 discrete I/O (F.MIO) # Certifications F.TI0 Zone 1 marking: II 2(1)G Ex ia [ia Ga] IIC T4 Gb F.MIO Zone 1 marking: II 2(1)G Ex ib [ia Ga] IIC T4 Gb Zone 1 certificate: PTB 07 ATEX 1061 X Zone 2 certificate: PTB 17 ATEX 1011 X # Mechanical Enclosure: Polyester GRP, electropolished 316 or brushed 316L stainless steel Degree of protection: IP66 Cable entries: M20 cable glands or stopping plugs
{"v":1,"colonne":[{"nome":"Type","valori":["Temp. multi-input","Multi-I/O","FieldBarrier FB1","Segment Protector","Passive","Engineered"]},{"nome":"Enclosure","valori":["Polyester GRP","SS electropolished","SS brushed","–"]},{"nome":"Bus","valori":["FF H1","PROFIBUS PA","FF H1 / PA","–"]},{"nome":"Installation","valori":["Zone 1","Zone 2","–"]}],"righe":[["F.TI0.P12.A08.F.0.GA2.GA2.D100",0,0,0,0],["F.TI0.P12.A08.F.0.GP2.GP2.C000",0,0,0,0],["F.TI0.P12.B08.F.0.H03.H03.0100",0,0,0,1],["F.TI0.P12.B08.P.0.GP2.GP2.0000",0,0,1,1],["F.TI0.P12.B08.P.0.GP2.GP2.0100",0,0,1,1],["F.TI0.S12.A08.F.0.GA2.GA2.D100",0,1,0,0],["F.TI0.S12.A08.F.0.GB2.GB2.B000",0,1,0,0],["F.TI0.S12.A08.F.0.GN2.GN2.A000",0,1,0,0],["F.TI0.S12.A08.F.0.GN2.GN2.A100",0,1,0,0],["F.TI0.S12.A08.F.0.GP2.GP2.0100",0,1,0,0],["F.TI0.S12.A08.F.0.GS2.GS2.D100",0,1,0,0],["F.TI0.S12.A08.F.0.H02.H02.D000",0,1,0,0],["F.TI0.S12.A08.F.0.H03.H03.0000",0,1,0,0],["F.TI0.S12.A08.P.0.GB2.GB2.0000",0,1,1,0],["F.TI0.S12.A08.P.0.GP2.GP2.0100",0,1,1,0],["F.TI0.S12.B08.F.0.GB2.GB2.0000",0,1,0,1],["F.TI0.S12.B08.F.0.GN2.GN2.D000",0,1,0,1],["F.TI0.S12.B08.F.0.GN2.GN2.D100",0,1,0,1],["F.TI0.S12.B08.F.0.H03.H03.0000",0,1,0,1],["F.TI0.S12.B08.P.0.GP2.GP2.0100",0,1,1,1],["F.TI0.S12.B08.P.0.GS2.GS2.D100",0,1,1,1],["F.TI0.T12.A08.F.0.GB2.GB2.B000",0,2,0,0],["F.TI0.T12.A08.F.0.GN2.GN2.A100",0,2,0,0],["F.TI0.T12.A08.F.0.GS2.GS2.D100",0,2,0,0],["F.TI0.T12.A08.F.0.H03.H03.D100",0,2,0,0],["F.TI0.T12.B08.F.0.GN2.GN2.D100",0,2,0,1],["F.MIO.P12.A12.F.0.GP2.GP2.0000",1,0,0,0],["F.MIO.P12.A12.F.0.GP2.GP2.0200",1,0,0,0],["F.MIO.P12.A12.F.0.H02.H02.C100",1,0,0,0],["F.MIO.P12.A12.F.0.H02.H02.C200",1,0,0,0],["F.MIO.P12.A12.P.0.GP2.GP2.0000",1,0,1,0],["F.MIO.P12.A12.P.0.GP2.GP2.0100",1,0,1,0],["F.MIO.P12.A12.P.0.GP2.GP2.C100",1,0,1,0],["F.MIO.P12.A12.P.0.GP2.GP2.D000",1,0,1,0],["F.MIO.P12.G12.F.3.H02.H02.D200",1,0,0,0],["F.MIO.T12.A12.F.0.H02.H02.0000",1,2,0,0],["F.MIO.T12.A12.P.0.GB2.GB2.0000",1,2,1,0],["F.MIO.T12.A12.P.0.GP2.GP2.D000",1,2,1,0],["F.MIO.T12.G12.F.0.H04.H04.C100",1,2,0,0],["FB1.P14.A08.1.3.GP2.GP2.B000",2,0,2,0],["268459-100031",3,3,3,2],["F4-JB-1.CG",4,3,3,2],["PSC2.FJB.SR484816.Y-922253",5,3,3,2]],"fonte":"Pepperl+Fuchs price list 2026 / official documentation"}
No items found.
Oil & Gas
Oil & Gas
Chemical and petrochemical
Chemical and petrochemical
Pharmaceutical
Pharmaceutical
FieldConnex Multi-I/O and Temperature Multi-Input junction boxes – Zone 1 and Zone 2