Zone 1
Explosive gas atmosphere likely to occur in normal operation
Zone 2
Explosive gas atmosphere unlikely to occur and, if it does, only for a short period
Zone 21
Explosive dust atmosphere likely to occur in normal operation
Zone 22
Explosive dust atmosphere unlikely to occur and, if it does, only for a short period
# General
Product type: Flexible heating jacket for hazardous areas
Containers: 25 L, 50 L, 100 L, 205 L drums · 1000 L IBCs (plastic bottle and metal cage) · 50 L gas cylinders
# Certifications
T4 marking: II 2 G D Ex eb IIC T4 Gb · Ex tb IIIC T135°C Db
T3 / IH marking: II 2 G D Ex eb IIC T3 Gb · Ex tb IIIC T200°C Db
Certificates: CML 13ATEX3018X · IECEx CML 14.0020X · CML 21UKEX3412X
Standards: EN IEC 60079-0:2018, EN IEC 60079-7:2015+A1:2018, EN 60079-31:2014
Markings: CE, UKCA, ATEX, IECEx, UKEX
# Electrical
Power supply: Single-phase up to 240 V, 50/60 Hz
Power: From 90 W (IHF/A/T4) to 2,500 W (IHF-C/IBC/T4)
Control: Self-limiting · certified 0-50 °C thermostat (IHF-R T4) · adjustable thermostat (IHF-R T3) · ProxATEX digital
Insulation class: Class II
Power cable: 5 m
# Environmental
Ingress protection: IP54, indoor or sheltered use
Certified ambient temperature: -20 °C to +40 °C
{"v":1,"marca":"LMK Thermosafe","colonne":[{"nome":"Container","valori":["25 L drums","50 L drums","100 L drums","205 L drums","50 L gas cylinders","IBC 1000 L"]},{"nome":"Version","valori":["IHF – self-limiting","IHF-R – 0-50 °C thermostat","IHF IH – self-limiting","IHF-R – adjustable thermostat","IHF-R – with ProxATEX","IHF-C – high power with ProxATEX"]},{"nome":"Temperature class","valori":["T4 / T135 °C","T3 / T200 °C"]}],"righe":[["1916",0,0,0,0],["1917",0,1,0,1],["1970",0,3,1,2],["1918",1,0,0,3],["1921",1,1,0,4],["1971",1,3,1,5],["1920",2,0,0,6],["1919",2,1,0,7],["1972",2,3,1,8],["2505",3,0,0,9],["2506",3,1,0,10],["1976",3,2,1,11],["1973",3,3,1,12],["1881",3,4,1,13],["1884",3,5,0,14],["1902",4,0,0,15],["1906",4,1,0,16],["1974",4,3,1,17],["2514",5,0,0,18],["2515",5,1,0,19],["1977",5,2,1,20],["1975",5,3,1,21],["1882",5,4,1,22],["1885",5,5,0,23]],"descrizioni":["IHF/A/T4 – 90 W, self-limiting +40 °C","IHF-R/A/T4 – 90 W, 0-50 °C thermostat","IHF-R/A/T3 – 160 W, adjustable thermostat","IHF/B/T4 – 130 W, self-limiting +40 °C","IHF-R/B/T4 – 130 W, 0-50 °C thermostat","IHF-R/B/T3 – 275 W, adjustable thermostat","IHF/C/T4 – 150 W, self-limiting +40 °C","IHF-R/C/T4 – 150 W, 0-50 °C thermostat","IHF-R/C/T3 – 295 W, adjustable thermostat","IHF/D/T4 – 540 W, self-limiting +50 °C","IHF-R/D/T4 – 540 W, 0-50 °C thermostat","IHF/D/IH – 620 W, self-limiting approx. +60 °C","IHF-R/D/T3 – 685 W, adjustable thermostat","IHF-R/D/T3 + ProxATEX – 685 W, ProxATEX mounted on the jacket","IHF-C/D/T4 – 1,800 W, wall-mounted ProxATEX","IHF/G/T4 – 100 W, self-limiting +30 °C","IHF-R/G/T4 – 100 W, 0-50 °C thermostat","IHF-R/G/T3 – 285 W, adjustable thermostat","IHF/IBC/T4 – 960 W, self-limiting +20 °C","IHF-R/IBC/T4 – 960 W, 0-50 °C thermostat","IHF/IBC/IH – 1,400 W, self-limiting approx. +35-40 °C","IHF-R/IBC/T3 – 1,620 W, adjustable thermostat 0-65 °C","IHF-R/IBC/T3 + ProxATEX – 1,620 W, ProxATEX mounted on the jacket","IHF-C/IBC/T4 – 2,500 W, wall-mounted ProxATEX"],"sprite":{"url":"https://cdn.prod.website-files.com/6aa55eca30c5bd4a1e486a4c/6ad4b6ea097bc8809fff4489_LMK-ihf-sprite.jpg","colonne":5,"lato":200},"accessori":[["1203","Insulated lid for 1000 L IBC, recommended with IHF IBC jackets",null],["1464","Insulated lid for 200 L drum",null]],"opzioni":[["IHF-C special sizes","Custom jackets for containers, tanks, pipework, valves and surfaces, with ATEX/IECEx digital controller"],["Mobile stand","Certified mobile stand for the ProxATEX controller"],["Other certifications","C1Z1 (UL/CSA), CCC and JPEx versions on request"]]}