# General
Type: Control cable for intrinsically safe circuits (Ex i)
Application: IEC 60079-14:2013 / EN 60079-14:2014 / VDE 0165-1:2014, clause 16.2.2
Standard reference: Based on EN 50525-2-51
Constructions: 2 to 25 cores · 0.75 – 1 – 1.5 mm² · with or without green/yellow earth conductor
# Construction
Conductor: Fine-wire bare copper, class 5 (VDE 0295 / IEC 60228)
Core insulation: PVC P8/1
Core identification: Black with white numbers (VDE 0293-334)
Outer sheath: Blue PVC, similar to RAL 5015
# Electrical
Rated voltage: U0/U 300/500 V
Test voltage: 3,000 V core/core
Mutual capacitance: approx. 140 nF/km core/core
Inductance: approx. 0.52 mH/km
# Mechanical
Minimum bending radius: fixed installation 4 × outer Ø · occasional flexing 15 × outer Ø
# Environmental
Temperature, fixed installation: -40…+80 °C
Temperature, occasional flexing: -5…+70 °C
UV and weather resistance: ISO 4892-3
Fire behaviour: Flame retardant to IEC 60332-1-2
{"v":1,"colonne":[{"nome":"Cores","valori":["2","3","4","5","7","12","18","25"]},{"nome":"Cross-section","valori":["0.75 mm²","1 mm²","1.5 mm²"]},{"nome":"Earth conductor","valori":["Without (X)","With green/yellow (G)"]}],"righe":[["0012420",0,0,0],["0012421",1,0,0],["0012430",2,0,0],["0012422",3,0,0],["0012423",4,0,0],["0012425",5,0,0],["0012427",6,0,0],["0012429",7,0,0],["0012440",0,1,0],["0012441",1,1,0],["0012443",3,1,0],["0012444",4,1,0],["0012446",5,1,0],["0012448",6,1,0],["0012401",0,2,0],["0012402",1,2,0],["0012403",2,2,0],["0012404",3,2,0],["0012501",1,2,1],["0012502",2,2,1],["0012503",3,2,1],["0012504",4,2,1],["0012505",5,2,1],["0012506",6,2,1],["0012507",7,2,1]],"descrizioni":["2 X 0.75 mm² · outer Ø 5.4 mm · weight 50 kg/km · copper 14.7 kg/km","3 X 0.75 mm² · outer Ø 5.7 mm · weight 60 kg/km · copper 22.1 kg/km","4 X 0.75 mm² · outer Ø 6.2 mm · weight 81 kg/km · copper 29.4 kg/km","5 X 0.75 mm² · outer Ø 6.7 mm · weight 88 kg/km · copper 36.8 kg/km","7 X 0.75 mm² · outer Ø 7.3 mm · weight 115 kg/km · copper 51.5 kg/km","12 X 0.75 mm² · outer Ø 9.9 mm · weight 185 kg/km · copper 88.2 kg/km","18 X 0.75 mm² · outer Ø 11.7 mm · weight 282 kg/km · copper 132.3 kg/km","25 X 0.75 mm² · outer Ø 13.8 mm · weight 393 kg/km · copper 183.8 kg/km","2 X 1 mm² · outer Ø 5.7 mm · weight 57 kg/km · copper 19.7 kg/km","3 X 1 mm² · outer Ø 6 mm · weight 73 kg/km · copper 29.6 kg/km","5 X 1 mm² · outer Ø 7.1 mm · weight 105 kg/km · copper 49.4 kg/km","7 X 1 mm² · outer Ø 8 mm · weight 138 kg/km · copper 69.1 kg/km","12 X 1 mm² · outer Ø 10.5 mm · weight 231 kg/km · copper 118.4 kg/km","18 X 1 mm² · outer Ø 12.7 mm · weight 331 kg/km · copper 177.7 kg/km","2 X 1.5 mm² · outer Ø 6.3 mm · weight 80 kg/km · copper 29 kg/km","3 X 1.5 mm² · outer Ø 6.7 mm · weight 105 kg/km · copper 43 kg/km","4 X 1.5 mm² · outer Ø 7.2 mm · weight 125 kg/km · copper 58 kg/km","5 X 1.5 mm² · outer Ø 8.1 mm · weight 139 kg/km · copper 72 kg/km","3 G 1.5 mm² · outer Ø 6.7 mm · weight 105 kg/km · copper 43 kg/km","4 G 1.5 mm² · outer Ø 7.2 mm · weight 125 kg/km · copper 58 kg/km","5 G 1.5 mm² · outer Ø 8.1 mm · weight 139 kg/km · copper 72 kg/km","7 G 1.5 mm² · outer Ø 8.9 mm · weight 180 kg/km · copper 101 kg/km","12 G 1.5 mm² · outer Ø 12 mm · weight 339 kg/km · copper 173 kg/km","18 G 1.5 mm² · outer Ø 14.4 mm · weight 513 kg/km · copper 259 kg/km","25 G 1.5 mm² · outer Ø 16.9 mm · weight 698 kg/km · copper 360 kg/km"],"opzioni":[["Packaging","Coil up to 30 kg or 250 m, or drum: tell us the lengths you need (e.g. 1 × 500 m or 5 × 100 m)."],["Cable glands","For enclosure entries pair the cable with blue polyamide glands for Ex i circuits: see Cabling › Plastic Cable Glands."]],"fonte":"Catalogo costruttore (ottobre 2026)"}