HW a 0 b c - d e f

Ex d junction box in aluminium or stainless steel with 1 or 2 integrated RX or UX barriers to extend RF coaxial cables to antennas in the hazardous area.

ATEX
IECEx
cQPSus
Class I Div 1
Class II Div 1
Description
Technical Specifications
Applications
Download
Datasheets

HWA and HWS junction boxes solve the routing of a coaxial cable from the safe area to an antenna in the hazardous area, or its extension in the field. The RX (low frequencies) or UX (above 1 GHz) barriers fitted on the box make the output intrinsically safe, so a standard antenna can be used.

Key features

  • 1 or 2 integrated RX or UX antenna barriers
  • Ex d enclosure in painted aluminium (HWA) or AISI 316 stainless steel (HWS), IP66/68
  • N male or N female internal connector
  • 3/4" NPT or M25x1.5 entries
  • Temperature -40 °C to +80 °C

Use the filters in the Variants and codes section to find the exact part number. Prices are available on request: contact us for a quotation or for different configurations.

Zone 1
Explosive gas atmosphere likely to occur in normal operation
Zone 2
Explosive gas atmosphere unlikely to occur and, if it does, only for a short period
Zone 21
Explosive dust atmosphere likely to occur in normal operation
Zone 22
Explosive dust atmosphere unlikely to occur and, if it does, only for a short period
Class I Division 1
Area where flammable gases or vapours are present under normal operating conditions
Class I Division 2
Area where flammable gases or vapours are present only under abnormal conditions
# General Type: Ex d RF junction box with antenna barriers Barriers: 1 × RXN · 2 × RXN · 1 × UXN · 2 × UXN Internal connector: N male · N female # Certifications ATEX: FIDI 20 ATEX 0014 · II 2(1)G Ex db mb [ia Ga] IIC T6…T5 Gb · II 2(1)D Ex mb tb [ia Da] IIIC T80…T100 °C Db IECEx: IECEx EXA 14.0001 USA & Canada: cQPS LT1504-1R2 · Cl. I Div. 1 Gr. B, C, D · Cl. II Div. 1 Gr. E, F, G # Electrical Impedance: 50 Ω Maximum voltage: 125 Vdc / 250 Vac # Mechanical Enclosure: Painted aluminium (HWA) · Electropolished AISI 316 CF8M stainless steel (HWS) Cable entries: 4 × 3/4" NPT-F · 4 × M25x1.5 Weight: 2.1 kg (HWA) · 4.8 kg (HWS) with 1 barrier # Environmental Ambient temperature: -40 °C to +80 °C Ingress protection: IP66/68
{"v":1,"marca":"","colonne":[{"nome":"Enclosure","valori":["Painted aluminium (HWA)","Electropolished AISI 316 stainless steel (HWS)"]},{"nome":"Internal connector","valori":["N male","N female"]},{"nome":"Antenna barriers","valori":["1 RXN barrier (N female) – layout 2","1 UXN barrier (N female) – layout 2","2 RXN barriers (N female) – layout 3","2 UXN barriers (N female) – layout 3"]},{"nome":"Cable entries","valori":["4 × 3/4\" NPT-F","4 × M25x1.5"]},{"nome":"Approvals","valori":["cQPS Cl. I Div. 1 + North American Zones","ATEX/IECEx gas and dust","ATEX/IECEx gas, dust and mining"]}],"righe":[["HWA00703-421N0",0,0,0,0,0,7],["HWA00703-421X0",0,0,0,0,1,7],["HWA00703-441N0",0,0,0,1,0,7],["HWA00703-441X0",0,0,0,1,1,7],["HWA00708-421N0",0,0,1,0,0,7],["HWA00708-421X0",0,0,1,0,1,7],["HWA00708-441N0",0,0,1,1,0,7],["HWA00708-441X0",0,0,1,1,1,7],["HWA00733-421N0",0,0,2,0,0,7],["HWA00733-421X0",0,0,2,0,1,7],["HWA00733-441N0",0,0,2,1,0,7],["HWA00733-441X0",0,0,2,1,1,7],["HWA00788-421N0",0,0,3,0,0,7],["HWA00788-421X0",0,0,3,0,1,7],["HWA00788-441N0",0,0,3,1,0,7],["HWA00788-441X0",0,0,3,1,1,7],["HWA00803-421N0",0,1,0,0,0,7],["HWA00803-421X0",0,1,0,0,1,7],["HWA00803-441N0",0,1,0,1,0,7],["HWA00803-441X0",0,1,0,1,1,7],["HWA00808-421N0",0,1,1,0,0,7],["HWA00808-421X0",0,1,1,0,1,7],["HWA00808-441N0",0,1,1,1,0,7],["HWA00808-441X0",0,1,1,1,1,7],["HWA00833-421N0",0,1,2,0,0,7],["HWA00833-421X0",0,1,2,0,1,7],["HWA00833-441N0",0,1,2,1,0,7],["HWA00833-441X0",0,1,2,1,1,7],["HWA00888-421N0",0,1,3,0,0,7],["HWA00888-421X0",0,1,3,0,1,7],["HWA00888-441N0",0,1,3,1,0,7],["HWA00888-441X0",0,1,3,1,1,7],["HWS00703-42EM0",1,0,0,0,2,7],["HWS00703-42EN0",1,0,0,0,0,7],["HWS00703-42EX0",1,0,0,0,1,7],["HWS00708-42EM0",1,0,1,0,2,7],["HWS00708-42EN0",1,0,1,0,0,7],["HWS00708-42EX0",1,0,1,0,1,7],["HWS00733-42EM0",1,0,2,0,2,7],["HWS00733-42EN0",1,0,2,0,0,7],["HWS00733-42EX0",1,0,2,0,1,7],["HWS00788-42EM0",1,0,3,0,2,7],["HWS00788-42EN0",1,0,3,0,0,7],["HWS00788-42EX0",1,0,3,0,1,7],["HWS00803-42EM0",1,1,0,0,2,7],["HWS00803-42EN0",1,1,0,0,0,7],["HWS00803-42EX0",1,1,0,0,1,7],["HWS00808-42EM0",1,1,1,0,2,7],["HWS00808-42EN0",1,1,1,0,0,7],["HWS00808-42EX0",1,1,1,0,1,7],["HWS00833-42EM0",1,1,2,0,2,7],["HWS00833-42EN0",1,1,2,0,0,7],["HWS00833-42EX0",1,1,2,0,1,7],["HWS00888-42EM0",1,1,3,0,2,7],["HWS00888-42EN0",1,1,3,0,0,7],["HWS00888-42EX0",1,1,3,0,1,7]],"accessori":[["KM-01","Stainless steel pole mounting kit for SWA/SWS/HWA/HWS enclosures, poles up to 2\" (50 mm)",24],["KM-02","Universal stainless steel wall mounting kit for SWA/SWS/HWA/HWS enclosures",24]],"opzioni":[["Codes","Codes built from datasheet B00018-04: to be confirmed in the quotation"]],"fonte":"manufacturer configurator and datasheets (October 2026)","sprite":{"url":"https://cdn.prod.website-files.com/6aa55eca30c5bd4a1e486a4c/6ad9046fb5b3225595fa62f0_solexy-varianti-sprite.jpg","colonne":10,"lato":200}}
Documentation by version
ATEX certificate for enclosures
HWA / HWS RF junction box
Documentation by version
IECEx certificate for enclosures
HWA / HWS RF junction box
Oil & Gas
Oil & Gas
Chemical and petrochemical
Chemical and petrochemical
Mining
Mining
Marine and offshore
Marine and offshore