# General
Type: Bistable NAMUR solenoid valves, 5/2 and 5/3-way
Available models: 10
# Technical features
Interface: NAMUR
Ports: G1/4
Function: 5/2 or 5/3-way (closed, exhausted, pressurised centre)
Body: aluminium
Medium: filtered compressed air, lubricated or not (class 5 ISO 8573-1)
{"modelli":{"f":[["Protection",["Safe area (non-Ex)","Ex ia – intrinsic safety","Ex db mb – flameproof with encapsulation","Ex ec / Ex tc – Zone 2 and 22"]],["Function",["5/2-way","5/3-way, closed centre","5/3-way, exhausted centre","5/3-way, pressurised centre"]],["Minimum temperature",["down to -10 °C","down to -20 °C"]]],"r":[["","5/2-way, G1/4, aluminium body, 24 V DC 3 W coil, -10…+50 °C",[[0],[0],[0]],0,"https://cdn.prod.website-files.com/6aa55eca30c5bd4a1e486a4c/6ae397f3b078c39c45b7f9ba_elettrovalvole-namur-bistabili-schede-tecniche.pdf#page=1",""],["","5/3-way, closed centre, G1/4, aluminium body, 24 V DC 3 W coil, -10…+50 °C",[[0],[1],[0]],0,"https://cdn.prod.website-files.com/6aa55eca30c5bd4a1e486a4c/6ae397f3b078c39c45b7f9ba_elettrovalvole-namur-bistabili-schede-tecniche.pdf#page=2",""],["","5/3-way, exhausted centre, G1/4, aluminium body, 24 V DC 3 W coil, -10…+50 °C",[[0],[2],[0]],0,"https://cdn.prod.website-files.com/6aa55eca30c5bd4a1e486a4c/6ae397f3b078c39c45b7f9ba_elettrovalvole-namur-bistabili-schede-tecniche.pdf#page=3",""],["","5/3-way, pressurised centre, G1/4, aluminium body, 24 V DC 3 W coil, -10…+50 °C",[[0],[3],[0]],0,"https://cdn.prod.website-files.com/6aa55eca30c5bd4a1e486a4c/6ae397f3b078c39c45b7f9ba_elettrovalvole-namur-bistabili-schede-tecniche.pdf#page=4",""],["","Ex ec/tc – 5/2-way, G1/4, aluminium body, 24 V DC 3 W coil, -10…+50 °C",[[3],[0],[0]],0,"https://cdn.prod.website-files.com/6aa55eca30c5bd4a1e486a4c/6ae397f3b078c39c45b7f9ba_elettrovalvole-namur-bistabili-schede-tecniche.pdf#page=5","II 3G Ex ec IIC T5 Gc · II 3D Ex tc IIIC T95°C Dc"],["","Ex ec/tc – 5/3-way, closed centre, G1/4, aluminium body, 24 V DC 3 W coil, -10…+50 °C",[[3],[1],[0]],0,"https://cdn.prod.website-files.com/6aa55eca30c5bd4a1e486a4c/6ae397f3b078c39c45b7f9ba_elettrovalvole-namur-bistabili-schede-tecniche.pdf#page=6","II 3G Ex ec IIC T5 Gc · II 3D Ex tc IIIC T95°C Dc"],["","Ex ia – 5/2-way, G1/4, aluminium body, 24 V DC 1.6 W coil, with distance plate, -10…+50 °C",[[1],[0],[0]],1,"https://cdn.prod.website-files.com/6aa55eca30c5bd4a1e486a4c/6ae397f3b078c39c45b7f9ba_elettrovalvole-namur-bistabili-schede-tecniche.pdf#page=7","II 2G Ex ia IIC T6 Gb · II 2D Ex tb IIIC T80°C Db"],["","Ex ia – 5/3-way, closed centre, G1/4, aluminium body, 24 V DC 1.6 W coil, with distance plate, -20…+50 °C",[[1],[1],[1]],1,"https://cdn.prod.website-files.com/6aa55eca30c5bd4a1e486a4c/6ae397f3b078c39c45b7f9ba_elettrovalvole-namur-bistabili-schede-tecniche.pdf#page=8","II 2G Ex ia IIC T6 Gb · II 2D Ex tb IIIC T80°C Db"],["","Ex db mb – 5/2-way, G1/4, aluminium body, 24 V DC 3 W coil, -10…+50 °C",[[2],[0],[0]],2,"https://cdn.prod.website-files.com/6aa55eca30c5bd4a1e486a4c/6ae397f3b078c39c45b7f9ba_elettrovalvole-namur-bistabili-schede-tecniche.pdf#page=9","II 2G Ex db mb IIC T5 Gb X · II 2D Ex tb IIIC T95°C Db X"],["","Ex db mb – 5/3-way, closed centre, G1/4, aluminium body, 24 V DC 3 W coil, with distance plate, -20…+50 °C",[[2],[1],[1]],2,"https://cdn.prod.website-files.com/6aa55eca30c5bd4a1e486a4c/6ae397f3b078c39c45b7f9ba_elettrovalvole-namur-bistabili-schede-tecniche.pdf#page=10","II 2G Ex db mb IIC T5 Gb X · II 2D Ex tb IIIC T95°C Db X"]],"s":{"u":"https://cdn.prod.website-files.com/6aa55eca30c5bd4a1e486a4c/6ae397fc54ba9466bcc1c3cc_mfv-elettrovalvole-namur-bistabili.jpg","c":3},"p":"","nc":1}}