Zone 1
Explosive gas atmosphere likely to occur in normal operation
Zone 2
Explosive gas atmosphere unlikely to occur and, if it does, only for a short period
Class I Division 1
Area where flammable gases or vapours are present under normal operating conditions
Class I Division 2
Area where flammable gases or vapours are present only under abnormal conditions
# Certifications
ATEX: II 2G Ex ia op is IIC T4 Gb
IECEx: Ex ia op is IIC T4 Gb
UKCA Ex: II 2G Ex ia op is IIC T4 Gb
NEC/CEC (SGS): Class I, Division 1, Groups A,B,C,D T4 · Class I, Zone 0, AEx ia op is IIC T4 Ga
Other approvals: Inmetro, PCEC (China)
# Measurement
Infrared range: -40 °C to +800 °C
Display resolution: 0.1 °C
Response time: < 500 ms
D:S ratio: 50:1
Accuracy: > 0 °C ± 1 °C or ± 1% (whichever is greater)
Emissivity: digital, 0.10 to 1.00 in 0.01 steps
Memory: up to 99 points with date and time
Functions: Min / Max / Avg / Diff
Pointer: single-beam laser
# General
Power supply: 2 x AAA batteries (approved)
Battery life: 4 hours continuous operation
Ambient temperature: 0 °C to +50 °C
Weight: approx. 365 g
{"v":1,"marca":"ecom instruments","colonne":[{"nome":"Certification","valori":["ATEX / IECEx","ATEX / IEx","NEC / CEC","PCEC (China)"]}],"righe":[["70141507",0,29],["70143714",1,29],["70144612",2,29],["70144614",3,29]],"accessori":[],"datasheet":{"base":"https://files.pepperl-fuchs.com/webcat/navi/productInfo/pds/","pn":["70141507","70143714","70144612","70144614"],"noit":["70141507","70143714","70144612","70144614"]},"fonte":"P+F / ecom instruments codes (October 2026)","sprite":{"url":"https://cdn.prod.website-files.com/6aa55eca30c5bd4a1e486a4c/6ad8d58ceaac9134cb1db070_ecom-varianti-sprite.jpg","colonne":10,"lato":200}}