SafeSite Medium Intensity – Class I Div 2 LED obstruction lighting system (UL)
Tower obstruction lights
illuminazione-segnalazione-torri
Dialight

SafeSite Medium Intensity – Class I Div 2 LED obstruction lighting system (UL)

D564 · DHZ

Dialight SafeSite medium-intensity LED obstruction lighting system for Class I Div 2 hazardous locations, UL/CSA certified for North America: 2,000 cd L-864 red beacon, 20,000 cd L-864/L-865 red/white flash head, dedicated controllers and power supplies.

UL
CSA
cETLus
Class I Div 2
Class II Div 2
FAA
Description
Technical Specifications
Applications
Download
Datasheets

The SafeSite Medium Intensity is Dialight's medium-intensity aircraft obstruction lighting system for towers, stacks, flares, cranes and structures located in hazardous locations. The system is UL/CSA certified for the North American market (UL 844 / UL 1598, CSA C22.2, Class I Div 2) and verified to FAA, ICAO and Transport Canada; it is not ATEX/IECEx certified and must not be used in ATEX Zones.

Key features

  • L-864 red beacon (ICAO Type B/C), 2,000 cd, flashing or steady
  • Dual red/white L-864/L-865 flash head (ICAO Type A/B): 20,000 cd by day and at twilight, 2,000 cd at night
  • Controllers for red L-864/L-810 systems and for dual systems with up to 3, 4, 6 or 8 flash heads
  • Dedicated power supply for each flash head, 120-277 VAC or 125 VDC supply
  • Class I Div 2 flash head and beacon; controllers and power supply in NEMA 4X explosion-proof enclosure
  • Synchronisation of several lights from a single controller, Class I Div 2 photocell
  • Ambient temperature from -40 °C to +55 °C, IP66, 5-year warranty

Use the filters in the Variants and codes section to find the exact code; for other configurations, contact us.

No items found.
# General Product type: Medium-intensity LED aircraft obstruction lighting system for hazardous locations Market: North America (UL/CSA) Warranty: 5 years # Certifications Aviation standards: FAA AC 150/5345-43G (L-864, L-865) · ICAO Annex 14 Type A, B, C · Transport Canada CAR 621 Classification: Class I Div 2, Groups A, B, C, D (beacon and flash head; flash head also Class II Div 2, Groups F, G) · DHZCCTD8C80x0 controllers and DHZCPSD4C8 power supply in explosion-proof enclosure Class I Div 1 and Div 2, Groups B, C, D · DHZCCTR2C8000 red controller Class I Div 2, Groups A, B, C, D Temperature class: T4A (beacon) · T5 (flash head) · T6 (dual system controllers and power supply) · T4 (red controller, 135 °C) Certifications: UL 844, UL 1598, UL 8750, UL 1203, CSA C22.2 No. 137, No. 250, No. 30 (Intertek ETL listing) # Lighting Luminous intensity: Red night 2,000 cd (L-864) · white day 20,000 cd, white twilight 20,000 cd, white or red night 2,000 cd (L-865/L-864) Operation: Flashing (20 flashes/min; red controller 20, 30 or 40 flashes/min) or steady (red beacon) # Electrical Power supply: Beacon and red controller 120-240 VAC 50/60 Hz · dual system controllers and power supply 120-277 VAC 50/60 Hz or 125 VDC Power: Beacon 20 W steady, 3.3 W flashing · power supply 85 W (white day), 35 W (white night), 25 W (red night) · dual system controller 15 W · red controller 5 W Power factor: > 0.9 # Mechanical Diffuser: High-strength polycarbonate with UV-resistant, anti-scratch and chemical-resistant coating Mounting: Standard base with FAA bolt pattern Weight: Beacon 9.1 kg (20 lb) · flash head 11.8 kg (26 lb) · red controller 36 kg (80 lb) · dual system controller and power supply 82 kg (180 lb) # Environmental Ambient temperature: from -40 °C to +55 °C (-40 °F … +131 °F) Ingress protection: IP66 · NEMA 4X
{"v":1,"colonne":[{"nome":"Type","valori":["L-864 beacon","L-864/L-865 flash head","Controller","Power supply"]},{"nome":"System","valori":["Red (L-864 / L-810)","Dual red/white (L-864 / L-865)"]},{"nome":"Controller capacity","valori":["—","1 L-864 + 4 L-810 per port","Up to 3 flash heads","Up to 4 flash heads","Up to 6 flash heads","Up to 8 flash heads"]},{"nome":"Power supply","valori":["120-240 VAC","120-277 VAC / 125 VDC","Via power supply"]}],"righe":[["D564B13001",0,0,0,0,0],["DHZCCTR2C8000",2,0,1,0,0],["DHZBFHD4C",1,1,0,2,0],["DHZCCTD8C8030",2,1,2,1,0],["DHZCCTD8C8040",2,1,3,1,0],["DHZCCTD8C8060",2,1,4,1,0],["DHZCCTD8C8080",2,1,5,1,0],["DHZCPSD4C8",3,1,0,1,0]],"accessori":[["DHZB6000PEC","Long-life Class I Div 2 photocell, Groups B, C, D (T4A, NEMA 4X), one per controller"],["RTOER08001","Class I Div 2 red L-810 side light, single, 3.5 W, 12-48 VDC (for systems with L-864/L-865 controller)"],["RTOER08002","Class I Div 2 red L-810 side light, double, 7 W, 12-48 VDC (for systems with L-864/L-865 controller)"],["RTO-2R07-001","Class I Div 2 red L-810 side light, single, 6.5 W, 120-240 VAC (for red L-864 controller)"],["RTO-2R07-002","Class I Div 2 red L-810 side light, double, 13 W, 120-240 VAC (for red L-864 controller)"],["D1RW-BRKT-01","Intermediate bracket for tower leg, hot-dip galvanised steel, FAA bolt pattern"],["D1RW-BRKT-03","3' (914 mm) top mounting extension, hot-dip galvanised steel"],["D1RW-SHIELD-01","Ice shield for intermediate mounting, hot-dip galvanised steel"],["D1RW-SHIELD-02","Integral ice shield for D1RW-BRKT-01 bracket"],["D1RW-HFRM-01","H-frame adapter plate for controller or power supply, aluminium"]],"opzioni":[["Flash head","Configurable in the controller as dual red/white or white only"],["Power supply","One DHZCPSD4C8 power supply per flash head, connected with 4-conductor cable"],["Cable entries","Controller and power supply: 1 x 1-1/2\" NPT and 7 x 3/4\" NPT"]],"sprite":{"url":"https://cdn.prod.website-files.com/6aa55eca30c5bd4a1e486a4c/6ad61d7ce235603dfacf28fc_dialight-safesite-medium-intensity-ostacoli-sprite.jpg","colonne":1,"lato":200}}
Other documents
UL – Authorization to Mark beacon D564B13001 (UL 844, Class I Div 2)
Certificates and declarations
Other documents
UL – Authorization to Mark, DHZBFHxx flash head (UL 844, Class I Div 2)
Certificates and declarations
Other documents
UL – Authorization to Mark, DHZCCTR2C8xxx controller (Class I Div 2)
Certificates and declarations
Other documents
UL – Authorization to Mark, DHZB600xPEC photocell (Class I Div 2)
Certificates and declarations
Other documents
L-864/L-810 controller (A0/A1) for hazardous locations installation manual
Manuals
Other documents
Installation manual – L-865/L-864 power supply for hazardous locations (DHZCPSD4C8)
Manuals
Other documents
Installation manual – DHZB60xxPEC photocell
Manuals
Other documents
Mounting accessories for obstruction lights
Brochure/warranty
No applications listed.
SafeSite Medium Intensity – Class I Div 2 LED obstruction lighting system (UL)