CEAG GHG 512-515 – Ex plugs and sockets from 32 to 125 A for Zone 1/21
Plugs and sockets
connessione-prese-spine
CEAG

CEAG GHG 512-515 – Ex plugs and sockets from 32 to 125 A for Zone 1/21

GHG 512 · 514 · 515

CEAG GHG 512, 514 and 515 Ex plugs and sockets, 32, 63 and 125 A, for Zone 1/21 and 2/22, up to 690 V, plus multi-pole connectors.

ATEX
IECEx
CE
Description
Technical Specifications
Applications
Download
Datasheets

The larger CEAG interlocked sockets cover the supply of power loads in hazardous areas: GHG 512 (32 A), GHG 514 (63 A) and GHG 515 (125 A), all to IEC 60309.

Key features

  • ATEX and IECEx certified for Zone 1, 2, 21 and 22
  • GHG 512 32 A, GHG 514 63 A, GHG 515 125 A, up to 690 V
  • IP66, interlocked: the plug cannot be withdrawn under load
  • Self-cleaning multi-blade contacts, AC-3 switching category
  • Multi-pole connectors up to 21 poles also available

In the Variants and codes section you will find the 111 codes from the current Eaton CEAG price list: use the filters to find the exact code and request a quote. For versions not listed, accessories or availability, contact us.

Zone 1
Explosive gas atmosphere likely to occur in normal operation
Zone 2
Explosive gas atmosphere unlikely to occur and, if it does, only for a short period
Zone 21
Explosive dust atmosphere likely to occur in normal operation
Zone 22
Explosive dust atmosphere unlikely to occur and, if it does, only for a short period
# Certifications 32 A: II 2G Ex db eb IIC/IIB T6/T5 Gb 63 A: BVS 17 ATEX E 073 X · IECEx BVS 17.0062X 125 A: PTB 01 ATEX 1069 · IECEx BKI 04.0005 # Electrical Voltage: up to 690 V # Environmental Ingress protection: IP66 Ambient temperature: -55 °C to +55 °C (125 A: -20 °C to +40 °C)
{"v":1,"marca":"CEAG","colonne":[{"nome":"Type","valori":["Accessory","Wall-mounted socket","Flange socket","Inline socket","Plug"]},{"nome":"Current","valori":["10 A","16 A","32 A","63 A","125 A","—"]},{"nome":"Poles","valori":["3 poles","4 poles","5 poles","6 poles + PE","7 poles","21 poles","—"]},{"nome":"Voltage","valori":["200-250 V","250 V","346-415 V","380-415 V","480-500 V","500 V","600-690 V","—"]},{"nome":"Position (h)","valori":["5 h","6 h","7 h","9 h","—"]}],"righe":[["GHG 512 4409 R0001",1,2,1,0,3,18],["GHG 512 4409 R3001",1,2,1,0,3,18],["GHG 512 4409 R3003",1,2,1,0,3,18],["GHG 512 4406 R0001",1,2,1,3,1,18],["GHG 512 4406 R3001",1,2,1,3,1,18],["GHG 512 4406 R3003",1,2,1,3,1,18],["GHG 512 4406 R0501",1,2,1,3,1,18],["GHG 512 4407 R0001",1,2,1,4,2,18],["GHG 512 4407 R3001",1,2,1,4,2,18],["GHG 512 4407 R0501",1,2,1,4,2,18],["GHG 512 4405 R0001",1,2,1,6,0,18],["GHG 512 4405 R3001",1,2,1,6,0,18],["GHG 512 4405 R0501",1,2,1,6,0,18],["GHG 512 4506 R0001",1,2,2,2,1,18],["GHG 512 4506 R3001",1,2,2,2,1,18],["GHG 512 4506 R3003",1,2,2,2,1,18],["GHG 512 4506 R0501",1,2,2,2,1,18],["GHG 512 4506 R1001",1,2,2,0,1,18],["GHG 512 7409 R0001",4,2,1,0,3,18],["GHG 512 7406 R0001",4,2,1,3,1,18],["GHG 512 7407 R0001",4,2,1,4,2,18],["GHG 512 7405 R0001",4,2,1,6,0,18],["GHG 512 7506 R0001",4,2,2,2,1,18],["GHG 512 3409 R0001",3,2,1,0,3,18],["GHG 512 3406 R0001",3,2,1,3,1,18],["GHG 512 3407 R0001",3,2,1,4,2,18],["GHG 512 3405 R0001",3,2,1,6,0,18],["GHG 512 3506 R0001",3,2,2,2,1,18],["GHG 512 8409 R0001",2,2,1,0,3,18],["GHG 512 8406 R0001",2,2,1,3,1,18],["GHG 512 8407 R0001",2,2,1,4,2,18],["GHG 512 8405 R0001",2,2,1,6,0,18],["GHG 512 8506 R0001",2,2,2,2,1,18],["GHG 510 1901 R0004",0,2,0,7,4,18],["GHG 510 1901 R0005",0,2,2,7,4,18],["GHG 514 4409 R0001",1,3,6,0,3,18],["GHG 514 4409 R3001",1,3,1,0,3,18],["GHG 514 4409 R3101",1,3,1,0,3,18],["GHG 514 4406 R0001",1,3,1,3,1,18],["GHG 514 4406 R3001",1,3,1,3,1,18],["GHG 514 4406 R3101",1,3,1,3,1,18],["GHG 514 4406 R0501",1,3,1,3,1,18],["GHG 514 4406 R3017",1,3,1,3,1,18],["GHG 514 4406 R3117",1,3,1,3,1,18],["GHG 514 4407 R0001",1,3,1,4,2,18],["GHG 514 4407 R3001",1,3,1,4,2,18],["GHG 514 4407 R3103",1,3,1,4,2,18],["GHG 514 4407 R0501",1,3,1,4,2,18],["GHG 514 4407 R3003",1,3,6,4,2,18],["GHG 514 4405 R0001",1,3,1,6,0,18],["GHG 514 4405 R3001",1,3,1,6,0,18],["GHG 514 4405 R3101",1,3,1,6,0,18],["GHG 514 4405 R0501",1,3,1,6,0,18],["GHG 514 4405 R3002",1,3,1,6,0,18],["GHG 514 4405 R3102",1,3,1,6,0,18],["GHG 514 4506 R0001",1,3,2,2,1,18],["GHG 514 4506 R3001",1,3,2,2,1,18],["GHG 514 4506 R3101",1,3,2,2,1,18],["GHG 514 4506 R0501",1,3,2,2,1,18],["GHG 514 4506 R3006",1,3,2,2,1,18],["GHG 514 4506 R3106",1,3,2,2,1,18],["GHG 514 4406 R1001",1,3,1,3,1,18],["GHG 514 4407 R1001",1,3,1,5,2,18],["GHG 514 4506 R1001",1,3,2,0,1,18],["GHG 514 7409 R0001",4,3,1,0,3,18],["GHG 514 7406 R0001",4,3,1,3,1,18],["GHG 514 7407 R0001",4,3,1,4,2,18],["GHG 514 7405 R0001",4,3,1,6,0,18],["GHG 514 7506 R0001",4,3,2,2,1,18],["GHG 510 1901 R0006",0,5,1,7,4,18],["GHG 515 4409 R0001",1,4,1,0,3,18],["GHG 515 4409 R0501",1,4,1,0,3,18],["GHG 515 4409 R3001",1,4,1,0,3,18],["GHG 515 4406 R0001",1,4,1,3,1,18],["GHG 515 4406 R3001",1,4,1,3,1,18],["GHG 515 4406 R3003",1,4,1,3,1,18],["GHG 515 4406 R0501",1,4,1,3,1,18],["GHG 515 4407 R0001",1,4,1,4,2,18],["GHG 515 4407 R3001",1,4,1,4,2,18],["GHG 515 4407 R3002",1,4,1,4,2,18],["GHG 515 4407 R0501",1,4,1,4,2,18],["GHG 515 4405 R0001",1,4,1,6,0,18],["GHG 515 4405 R3001",1,4,1,6,0,18],["GHG 515 4405 R3002",1,4,1,6,0,18],["GHG 515 4405 R0501",1,4,1,6,0,18],["GHG 515 4506 R0001",1,4,2,2,1,18],["GHG 515 4506 R3001",1,4,2,2,1,18],["GHG 515 4506 R3005",1,4,2,2,1,18],["GHG 515 4506 R0501",1,4,2,2,1,18],["GHG 515 4506 R1001",1,4,2,0,1,18],["GHG 515 7409 R0001",4,4,1,0,3,18],["GHG 515 7406 R0001",4,4,1,3,1,18],["GHG 515 7407 R0001",4,4,1,4,2,18],["GHG 515 7405 R0001",4,4,1,6,0,18],["GHG 515 7506 R0001",4,4,2,2,1,18],["GHG 510 1901 R0007",0,4,1,7,4,18],["GHG 511 4905 R0001",1,0,5,7,0,18],["GHG 511 4906 R0001",1,0,5,7,1,18],["GHG 511 4907 R0001",1,0,5,7,2,18],["GHG 511 4905 R3001",1,0,5,7,0,18],["GHG 511 4906 R3001",1,0,5,7,1,18],["GHG 511 4907 R3001",1,0,5,7,2,18],["GHG 591 2201 R0001",4,5,5,1,0,18],["GHG 591 2201 R0002",4,5,5,1,1,18],["GHG 591 2201 R0003",4,5,5,1,2,18],["GHG 511 4706 R0001",1,1,4,7,1,18],["GHG 511 4706 R3001",1,1,4,7,1,18],["GHG 511 4707 R0003",1,1,3,7,2,18],["GHG 511 4707 R3003",1,1,3,7,2,18],["GHG 592 2001 R0002",4,1,4,1,1,18],["GHG 592 2001 R0022",4,1,4,1,2,18]],"descrizioni":["Ex wall-mounted socket for Zone 1/21, 32 A, 4 poles – 200-250 V, 9 h, 1 x M40 cable gland, 1 x M40 threaded plug","Ex wall-mounted socket for Zone 1/21, 32 A, 4 poles – 200-250 V, 9 h, 2 x M32 metal thread with threaded plug","Ex wall-mounted socket for Zone 1/21, 32 A, 4 poles – 200-250 V, 9 h, 2 x M20 metal thread with threaded plug","Ex wall-mounted socket for Zone 1/21, 32 A, 4 poles – 380-415 V, 6 h, 1 x M40 cable gland, 1 x M40 threaded plug","Ex wall-mounted socket for Zone 1/21, 32 A, 4 poles – 380-415 V, 6 h, 2 x M32 metal thread with threaded plug","Ex wall-mounted socket for Zone 1/21, 32 A, 4 poles – 380-415 V, 6 h, 2 x M32 metal thread with threaded plug","Ex wall-mounted socket for Zone 1/21, 32 A, 4 poles – 380-415 V, 6 h, 1 x M40 cable gland, 1 x M25 cable gland","Ex wall-mounted socket for Zone 1/21, 32 A, 4 poles – 480-500 V, 7 h, 1 x M40 cable gland, 1 x M40 threaded plug","Ex wall-mounted socket for Zone 1/21, 32 A, 4 poles – 480-500 V, 7 h, 2 x M32 metal thread with threaded plug","Ex wall-mounted socket for Zone 1/21, 32 A, 4 poles – 480-500 V, 7 h, 1 x M40 cable gland, 1 x M25 cable gland","Ex wall-mounted socket for Zone 1/21, 32 A, 4 poles – 600-690 V, 5 h, 1 x M40 cable gland, 1 x M40 threaded plug","Ex wall-mounted socket for Zone 1/21, 32 A, 4 poles – 600-690 V, 5 h, 2 x M32 metal thread with threaded plug","Ex wall-mounted socket for Zone 1/21, 32 A, 4 poles – 600-690 V, 5 h, 1 x M40 cable gland, 1 x M25 cable gland","Ex wall-mounted socket for Zone 1/21, 32 A, 5 poles – 346-415 V, 6 h, 1 x M40 cable gland, 1 x M40 threaded plug","Ex wall-mounted socket for Zone 1/21, 32 A, 5 poles – 346-415 V, 6 h, 2 x M32 metal thread with threaded plug","Ex wall-mounted socket for Zone 1/21, 32 A, 5 poles – 346-415 V, 6 h, 2 x M20 metal thread with threaded plug","Ex wall-mounted socket for Zone 1/21, 32 A, 5 poles – 346-415 V, 6 h, 1 x M40 cable gland, 1 x M25 cable gland","Ex wall-mounted socket for Zone 1/21, 32 A, 5 poles, stainless steel AISI 316L – 200-250 V / 380-415 V, 6 h, 0 x M32 metal thread with threaded plug","Ex plug for Zone 1/21, 32 A, 4 poles – 200-250 V, 9 h, 1 cable gland","Ex plug for Zone 1/21, 32 A, 4 poles – 380-415 V, 6 h, 1 cable gland","Ex plug for Zone 1/21, 32 A, 4 poles – 480-500 V, 7 h, 1 cable gland","Ex plug for Zone 1/21, 32 A, 4 poles – 600-690 V, 5 h, 1 cable gland","Ex plug for Zone 1/21, 32 A, 5 poles – 346-415 V, 6 h, 1 cable gland","Ex inline socket for Zone 1/21, 32 A, 4 poles – 200-250 V, 9 h, 1 cable gland","Ex inline socket for Zone 1/21, 32 A, 4 poles – 380-415 V, 6 h, 1 cable gland","Ex inline socket for Zone 1/21, 32 A, 4 poles – 480-500 V, 7 h, 1 cable gland","Ex inline socket for Zone 1/21, 32 A, 4 poles – 600-690 V, 5 h, 1 cable gland","Ex inline socket for Zone 1/21, 32 A, 5 poles – 346-415 V, 6 h, 1 cable gland","Ex flange socket for Zone 1/21, 32 A, 4 poles – 200-250 V, 9 h, 1 cable gland","Ex flange socket for Zone 1/21, 32 A, 4 poles – 380-415 V, 6 h, 1 cable gland","Ex flange socket for Zone 1/21, 32 A, 4 poles – 480-500 V, 7 h, 1 cable gland","Ex flange socket for Zone 1/21, 32 A, 4 poles – 600-690 V, 5 h, 1 cable gland","Ex flange socket for Zone 1/21, 32 A, 5 poles – 346-415 V, 6 h, 1 cable gland","Accessories for plugs and receptacles – plug cap 32 A 3-Pole/4-Pole","Accessories for plugs and receptacles – plug cap 32 A 5-Pole","Ex wall-mounted socket for Zone 1/21, 63 A – 200-250 V, 9 h, 1 x M50 cable gland threaded plug","Ex wall-mounted socket for Zone 1/21, 63 A, 4 poles, GHG 514 – 200-250 V, 9 h, 2 x M40 metal thread with threaded plug","Ex wall-mounted socket for Zone 1/21, 63 A, 4 poles, GHG 514 – 200-250 V, 9 h, 2 x M40 metal thread with threaded plug, -40 °C","Ex wall-mounted socket for Zone 1/21, 63 A, 4 poles, GHG 514 – 380-415 V, 6 h, 1 x M50 cable gland","Ex wall-mounted socket for Zone 1/21, 63 A, 4 poles, GHG 514 – 380-415 V, 6 h, 2 x M40 metal thread with threaded plug","Ex wall-mounted socket for Zone 1/21, 63 A, 4 poles, GHG 514 – 380-415 V, 6 h, 2 x M40 metal thread with threaded plug, -40 °C","Ex wall-mounted socket for Zone 1/21, 63 A, 4 poles, GHG 514 – 380-415 V, 6 h, 1 x M50 cable gland, 1 x M25 cable gland","Ex wall-mounted socket for Zone 1/21, 63 A, 4 poles, GHG 514 – 380-415 V, 6 h, 2 x M40 metal thread with threaded plug","Ex wall-mounted socket for Zone 1/21, 63 A, 4 poles, GHG 514 – 380-415 V, 6 h, 2 x M40 metal thread with threaded plug, external earth, -40 °C","Ex wall-mounted socket for Zone 1/21, 63 A, 4 poles, GHG 514 – 480-500 V, 7 h, 1 x M50 cable gland threaded plug","Ex wall-mounted socket for Zone 1/21, 63 A, 4 poles, GHG 514 – 480-500 V, 7 h, 2 x M40 metal thread with threaded plug","Ex wall-mounted socket for Zone 1/21, 63 A, 4 poles, GHG 514 – 480-500 V, 7 h, 2 x M40 metal thread with threaded plug, -40 °C","Ex wall-mounted socket for Zone 1/21, 63 A, 4 poles, GHG 514 – 480-500 V, 7 h, 1 x M50 cable gland threaded plug","Ex wall-mounted socket for Zone 1/21, 63 A – 480-500 V, 7 h, 2 x M40 metal thread with threaded plug","Ex wall-mounted socket for Zone 1/21, 63 A, 4 poles, GHG 514 – 600-690 V, 5 h, 1 x M50 cable gland, 1 threaded plug","Ex wall-mounted socket for Zone 1/21, 63 A, 4 poles, GHG 514 – 600-690 V, 5 h, 2 x M40 metal thread with threaded plug","Ex wall-mounted socket for Zone 1/21, 63 A, 4 poles, GHG 514 – 600-690 V, 5 h, 2 x M40 metal thread with threaded plug, -40 °C","Ex wall-mounted socket for Zone 1/21, 63 A, 4 poles, GHG 514 – 600-690 V, 5 h, 1 x M50 cable gland, 1 x M25 cable gland","Ex wall-mounted socket for Zone 1/21, 63 A, 4 poles, GHG 514 – 600-690 V, 5 h, 2 x M40 metal thread with threaded plug","Ex wall-mounted socket for Zone 1/21, 63 A, 4 poles, GHG 514 – 600-690 V, 5 h, 2 x M40 metal thread with threaded plug, external earth, -40 °C","Ex wall-mounted socket for Zone 1/21, 63 A, 5 poles – 346-415 V, 6 h, 1 x M50 cable gland threaded plug","Ex wall-mounted socket for Zone 1/21, 63 A, 5 poles – 346-415 V, 6 h, 2 x M40 metal thread with threaded plug","Ex wall-mounted socket for Zone 1/21, 63 A, 5 poles – 346-415 V, 6 h, 2 x M40 metal thread with threaded plug, -40 °C","Ex wall-mounted socket for Zone 1/21, 63 A, 5 poles – 346-415 V, 6 h, 1 x M50 cable gland, 1 x M25 cable gland","Ex wall-mounted socket for Zone 1/21, 63 A, 5 poles – 346-415 V, 6 h, 2 x M40 metal thread with threaded plug","Ex wall-mounted socket for Zone 1/21, 63 A, 5 poles – 346-415 V, 6 h, 2 x M40 metal thread with threaded plug, external earth, -40 °C","Ex wall-mounted socket for Zone 1/21, 63 A, 4 poles, Stainless steel AISI 316L, polyamide – 380-415 V, 6 h, 2 x M50 metal thread with threaded plug","Ex wall-mounted socket for Zone 1/21, 63 A, 4 poles, Stainless steel AISI 316L, polyamide – 500 V, 7 h, 2 x M50 metal thread with threaded plug","Ex wall-mounted socket for Zone 1/21, 63 A, 5 poles, Stainless steel AISI 316L, polyamide – 200-250 V / 380-415 V, 6 h, 2 x M50 metal thread with threaded plug","Ex plug for Zone 1/21, 63 A, 4 poles – 200-250 V, 9 h, 1 cable gland","Ex plug for Zone 1/21, 63 A, 4 poles – 380-415 V, 6 h, 1 cable gland","Ex plug for Zone 1/21, 63 A, 4 poles – 480-500 V, 7 h, 1 cable gland","Ex plug for Zone 1/21, 63 A, 4 poles – 600-690 V, 5 h, 1 cable gland","Ex plug for Zone 1/21, 63 A, 5 poles – 346-415 V, 6 h, 1 cable gland","Accessories for plugs and receptacles – plug cap 63 A4-Pole/5-Pole","Ex wall-mounted socket for Zone 1/21, 125 A, 4 poles – 200-250 V, 9 h, 2 x M63 cable gland","Ex wall-mounted socket for Zone 1/21, 125 A, 4 poles – 200-250 V, 9 h, 1 x M63 cable gland, 1 x M25 cable gland","Ex wall-mounted socket for Zone 1/21, 125 A, 4 poles – 200-250 V, 9 h, 2 x M50 cable gland","Ex wall-mounted socket for Zone 1/21, 125 A, 4 poles – 380-415 V, 6 h, 2 x M63 cable gland","Ex wall-mounted socket for Zone 1/21, 125 A, 4 poles – 380-415 V, 6 h, 2 x M50 cable gland","Ex wall-mounted socket for Zone 1/21, 125 A, 4 poles – 380-415 V, 6 h, 2 x M50 metal thread with threaded plug","Ex wall-mounted socket for Zone 1/21, 125 A, 4 poles – 380-415 V, 6 h, 1 x M63 cable gland, 1 x M25 cable gland","Ex wall-mounted socket for Zone 1/21, 125 A, 4 poles – 480-500 V, 7 h, 2 x M63 cable gland","Ex wall-mounted socket for Zone 1/21, 125 A, 4 poles – 480-500 V, 7 h, 2 x M50 cable gland","Ex wall-mounted socket for Zone 1/21, 125 A, 4 poles – 480-500 V, 7 h, 2 x M50 cable gland","Ex wall-mounted socket for Zone 1/21, 125 A, 4 poles – 480-500 V, 7 h, 1 x M63 cable gland, 1 x M25 cable gland","Ex wall-mounted socket for Zone 1/21, 125 A, 4 poles – 600-690 V, 5 h, 2 x M63 cable gland","Ex wall-mounted socket for Zone 1/21, 125 A, 4 poles – 600-690 V, 5 h, 2 x M50 cable gland","Ex wall-mounted socket for Zone 1/21, 125 A, 4 poles – 600-690 V, 5 h, 2 x M50 cable gland","Ex wall-mounted socket for Zone 1/21, 125 A, 4 poles – 600-690 V, 5 h, 1 x M63 cable gland, 1 x M25 cable gland","Ex wall-mounted socket for Zone 1/21, 125 A, 5 poles – 346-415 V, 6 h, 2 x M63 cable gland","Ex wall-mounted socket for Zone 1/21, 125 A, 5 poles – 346-415 V, 6 h, 2 x M50 cable gland","Ex wall-mounted socket for Zone 1/21, 125 A, 5 poles – 346-415 V, 6 h, 2 x M50 cable gland","Ex wall-mounted socket for Zone 1/21, 125 A, 5 poles – 346-415 V, 6 h, 1 x M63 cable gland, 1 x M25 cable gland","Ex wall-mounted socket for Zone 1/21, 125 A, 5 poles, Stainless steel AISI 316L, polyamide – 200-250 V / 380-415 V, 6 h, 2 x M50 metal thread with threaded plug","Ex plug for Zone 1/21, 125 A, 4 poles – 200-250 V, 9 h, 1 cable gland","Ex plug for Zone 1/21, 125 A, 4 poles – 380-415 V, 6 h, 1 cable gland","Ex plug for Zone 1/21, 125 A, 4 poles – 480-500 V, 7 h, 1 cable gland","Ex plug for Zone 1/21, 125 A, 4 poles – 600-690 V, 5 h, 1 cable gland","Ex plug for Zone 1/21, 125 A, 5 poles – 346-415 V, 6 h, 1 cable gland","Accessories for plugs and receptacles – plug cap 125 A 4-Pole/5-Pole","Ex wall-mounted socket for Zone 1/21, 10 A, 21 poles – 5 h, 1 x M40 cable gland","Ex wall-mounted socket for Zone 1/21, 10 A, 21 poles – 6 h, 1 x M40 cable gland","Ex wall-mounted socket for Zone 1/21, 10 A, 21 poles – 7 h, 1 x M40 cable gland","Ex wall-mounted socket for Zone 1/21, 10 A, 21 poles – 5 h, 1 x M32 cable gland","Ex wall-mounted socket for Zone 1/21, 10 A, 21 poles – 6 h, 1 x M32 metal thread, 1 threaded plug","Ex wall-mounted socket for Zone 1/21, 10 A, 21 poles – 7 h, 1 x M32 metal thread, 1 threaded plug","Ex plug for Zone 1/21, 10, 21 poles – 250 V, 5 h, 1 cable gland","Ex plug for Zone 1/21, 10, 21 poles – 250 V, 6 h, 1 cable gland","Ex plug for Zone 1/21, 10, 21 poles – 250 V, 7 h, 1 cable gland","Ex wall-mounted socket for Zone 1/21, max. 16 A (T6) / 20 A (T5), 7 poles – 6 h, Auxiliary contact: No, 1 x M40 polyamide","Ex wall-mounted socket for Zone 1/21, max. 16 A (T6) / 20 A (T5), 7 poles – 6 h, Auxiliary contact: No, 2 x M32 metal thread","Ex wall-mounted socket for Zone 1/21, max. 16 A (T6) / 20 A (T5), 6 poles + PE – 7 h, Auxiliary contact: No, 1 x M40 polyamide","Ex wall-mounted socket for Zone 1/21, max. 16 A (T6) / 20 A (T5), 6 poles + PE – 7 h, Auxiliary contact: No, 2 x M32 metal thread","Ex plug for Zone 1/21, max. 16 A (T6) / 20 A (T5), 7 poles – 250 V, 6 h, 1 cable gland","Ex plug for Zone 1/21, max. 16 A (T6) / 20 A (T5), 7 poles – 250 V, 7 h, 1 cable gland"],"opzioni":[["How to read the code","The code shown is the Eaton CEAG order number from the current price list. For different versions or accessories not listed, contact us."]],"sprite":{"url":"https://cdn.prod.website-files.com/6aa55eca30c5bd4a1e486a4c/6ada3d0b94066b8fc4df8a57_ceag-varianti-sprite.jpg","colonne":10,"lato":200}}