Services
Tools
Products
>
Modular switches
>
CEAG GHG 292-295 – 16 A Ex control switches with and without instrument
Modular switches
interruttori-modulari
CEAG

CEAG GHG 292-295 – 16 A Ex control switches with and without instrument

GHG 292 · 293 · 294 · 295

CEAG GHG 292-295 16 A Ex control switches for Zone 1/21, in GRP or aluminium, with or without AM 72 measuring instrument.

ATEX
IECEx
CE
Description
Technical Specifications
Applications
Download
Datasheets

GHG 29 control switches provide switching functions with up to 6 contacts and from 2 to 5 positions directly in the field. GHG 292 and 293 are in black polyester, GHG 294 and 295 in aluminium; 293 and 295 integrate the AM 72 instrument.

Key features

  • ATEX and IECEx certified for Zone 1, 2, 21 and 22
  • 16 A / 500 V (20 A / 690 V with GHG 28 switch)
  • Up to 6 contacts, from 2 to 5 positions
  • GHG 293 and 295 with AM 72 ammeter
  • GRP (292/293) or aluminium-silicon (294/295) enclosure, IP66

In the Variants and codes section you will find the 21 codes from the current Eaton CEAG price list: use the filters to find the exact code and request a quote. For versions not listed, accessories or availability, contact us.

Zone 1
Explosive gas atmosphere likely to occur in normal operation
Zone 2
Explosive gas atmosphere unlikely to occur and, if it does, only for a short period
Zone 21
Explosive dust atmosphere likely to occur in normal operation
Zone 22
Explosive dust atmosphere unlikely to occur and, if it does, only for a short period
# Certifications ATEX: PTB 99 ATEX 1163 — II 2G Ex ed ia IIC T5/T6 · II 2D Ex tD A21 IP66 T80 °C IECEx: IECEx BKI 07.0011 # Electrical Voltage/current: 500 V, 16 A # Mechanical Enclosures: black GRP (GHG 292/293) · aluminium RAL 7031 (GHG 294/295) # Environmental Ingress protection: IP66 Ambient temperature: -20 °C to +40 °C (option from -55 °C)
{"v":1,"marca":"CEAG","colonne":[{"nome":"Series","valori":["GHG 292","GHG 293","GHG 294","GHG 295"]},{"nome":"Measuring instrument","valori":["No","Yes"]}],"righe":[["GHG 292 1000 R0004",0,0,50],["GHG 292 1000 R0001",0,0,50],["GHG 292 2000 R0003",0,0,50],["GHG 292 1000 R0003",0,0,50],["GHG 292 1000 R0002",0,0,50],["GHG 292 2000 R0004",0,0,50],["GHG 292 2001 R0001",0,0,50],["GHG 292 2000 R0002",0,0,50],["GHG 292 2001 R4017",0,0,50],["GHG 293 1000 R0001",1,1,50],["GHG 293 1000 R0002",1,1,50],["GHG 294 1000 R0001",2,0,50],["GHG 294 1000 R0002",2,0,50],["GHG 294 1000 R0003",2,0,50],["GHG 294 1000 R0004",2,0,50],["GHG 294 2000 R0002",2,0,50],["GHG 294 2000 R0003",2,0,50],["GHG 294 2000 R0004",2,0,50],["GHG 294 2001 R0001",2,0,50],["GHG 295 1000 R0001",3,1,50],["GHG 295 1000 R0002",3,1,50]],"descrizioni":["Ex control switch 16 A, without measuring instrument, for Zone 1/21, GHG 292 – switch base 8067, 1 x M25 drilled enclosure, cable glands: 1 x M25 polyamide","Ex control switch 16 A, without measuring instrument, for Zone 1/21, GHG 292 – switch base 6062, 1 x M25 drilled enclosure, cable glands: 1 x M25 polyamide","Ex control switch 16 A, without measuring instrument, for Zone 1/21, GHG 292 – switch base 8037, 1 x M25 drilled enclosure, cable glands: 1 x M25 polyamide","Ex control switch 16 A, without measuring instrument, for Zone 1/21, GHG 292 – switch base 4067, 1 x M25 drilled enclosure, cable glands: 1 x M25 polyamide","Ex control switch 16 A, without measuring instrument, for Zone 1/21, GHG 292 – switch base 6065, 1 x M25 drilled enclosure, cable glands: 1 x M25 polyamide","Ex control switch 16 A, without measuring instrument, for Zone 1/21, GHG 292 – switch base 5024, 1 x M25 drilled enclosure, cable glands: 1 x M25 polyamide","Ex control switch 16 A, without measuring instrument, for Zone 1/21, GHG 292 – switch base 5023, 1 x M25 drilled enclosure, cable glands: 1 x M25 polyamide","Ex control switch 16 A, without measuring instrument, for Zone 1/21, GHG 292 – switch base 4037, 1 x M25 drilled enclosure, cable glands: 1 x M25 polyamide","Ex control switch 16 A, without measuring instrument, for Zone 1/21, GHG 292 – switch base 6065, 2 x M25 drilled enclosure, cable glands: 2 x M25 polyamide","Ex control switch 16 A, with measuring instrument, for Zone 1/21, GHG 293 – switch base 6062, 1 x M32 drilled enclosure, cable glands: 1 x M32 polyamide","Ex control switch 16 A, with measuring instrument, for Zone 1/21, GHG 293 – switch base 6065, 1 x M32 drilled enclosure, cable glands: 1 x M32 polyamide","Ex control switch 16 A, without measuring instrument, for Zone 1/21, GHG 294 – switch base 6062, 2 x M25 drilled enclosure, cable glands: 1 x M25 polyamide","Ex control switch 16 A, without measuring instrument, for Zone 1/21, GHG 294 – switch base 6065, 2 x M25 drilled enclosure, cable glands: 1 x M25 polyamide","Ex control switch 16 A, without measuring instrument, for Zone 1/21, GHG 294 – switch base 4067, 2 x M25 drilled enclosure, cable glands: 1 x M25 polyamide","Ex control switch 16 A, without measuring instrument, for Zone 1/21, GHG 294 – switch base 8067, 1 x M20 drilled enclosure, cable glands: 1 x M25 polyamide","Ex control switch 16 A, without measuring instrument, for Zone 1/21, GHG 294 – switch base 4037, 2 x M25 drilled enclosure, cable glands: 2 x M25 polyamide","Ex control switch 16 A, without measuring instrument, for Zone 1/21, GHG 294 – switch base 8037, 2 x M25 drilled enclosure, cable glands: 2 x M25 polyamide","Ex control switch 16 A, without measuring instrument, for Zone 1/21, GHG 294 – switch base 5024, 2 x M25 drilled enclosure, cable glands: 1 x M25 polyamide","Ex control switch 16 A, without measuring instrument, for Zone 1/21, GHG 294 – switch base 5023, 2 x M20 drilled enclosure, cable glands: 1 x M20 polyamide","Ex control switch 16 A, with measuring instrument, for Zone 1/21, GHG 295 – switch base 6062, 1 x M32 drilled enclosure, cable glands: 1 x M32 polyamide","Ex control switch 16 A, with measuring instrument, for Zone 1/21, GHG 295 – switch base 6065, 2 x M25 drilled enclosure, cable glands: 1 x M32 polyamide"],"opzioni":[["Versions on request","GHG 25/26/29 switching functions not listed can be supplied on request: tell us the diagram and current."],["How to read the code","The code shown is the Eaton CEAG order number from the current price list. For other versions or accessories not listed, contact us."]],"sprite":{"url":"https://cdn.prod.website-files.com/6aa55eca30c5bd4a1e486a4c/6ada3d0b94066b8fc4df8a57_ceag-varianti-sprite.jpg","colonne":10,"lato":200}}
No items found.
No applications listed.
CEAG GHG 292-295 – 16 A Ex control switches with and without instrument