Services
Tools
Products
>
Ex e junction and terminal boxes
>
CEAG GHG 791 – Ex e / Ex i polyamide junction and terminal boxes
Ex e junction and terminal boxes
custodie-morsettiere-ex-e
CEAG

CEAG GHG 791 – Ex e / Ex i polyamide junction and terminal boxes

GHG 791

CEAG GHG 791 junction and terminal boxes in black polyamide, Ex e and Ex i, for Zone 1/21 and 2/22, up to 12 terminals and 690 V.

ATEX
IECEx
CE
Description
Technical Specifications
Applications
Download
Datasheets

GHG 791 is CEAG's compact polyamide box for field branch connections and wiring. It is supplied ready-fitted with terminals and cable glands, in Ex e (grey terminals) or Ex i (blue terminals) versions.

Key features

  • ATEX and IECEx certified for Zone 1, 2, 21 and 22
  • GHG 791 01: 81.5 × 100 × 61 mm, up to 6 terminals, max 32 A
  • GHG 791 02: 117.5 × 113.5 × 73.5 mm, up to 12 terminals, max 28 A
  • Ex e and Ex i versions
  • Black polyamide, IP66, up to 690 V

In the Variants and codes section you will find the 32 codes from the current Eaton CEAG price list: use the filters to find the exact code and request a quote. For versions not listed, accessories or availability, contact us.

Zone 1
Explosive gas atmosphere likely to occur in normal operation
Zone 2
Explosive gas atmosphere unlikely to occur and, if it does, only for a short period
Zone 21
Explosive dust atmosphere likely to occur in normal operation
Zone 22
Explosive dust atmosphere unlikely to occur and, if it does, only for a short period
# Certifications ATEX: BVS 16 ATEX E 031 — II 2G Ex e IIC T5/T6 Gb · II 2D Ex tb IIIC T80 °C Db IECEx: IECEx BVS 16.0024 # Electrical Voltage: 690 V Current: GHG 791 01 max 32 A · GHG 791 02 max 28 A # Mechanical Material: black polyamide # Environmental Ingress protection: IP66 Ambient temperature: -20 °C to +40 °C (option -55 °C to +55 °C)
{"v":1,"marca":"CEAG","colonne":[{"nome":"Protection","valori":["Accessory","Ex e","Ex i"]},{"nome":"Size","valori":["GHG 791 01","GHG 791 02","—"]},{"nome":"Terminals","valori":["4 x 2.5 mm² + 2x2.5 mm²","4 x 4 mm² + 1x4 mm²","4 x 4 mm² + 2x4 mm²","6 x 2.5 mm² + 2x2.5 mm²","6 x 4 mm² + 2x4 mm²","8 x 4 mm² + 2x4 mm²","12 x 2.5 mm² + 2x2.5 mm²","—"]},{"nome":"Entries","valori":["1 × M25","1 × M32","2 × M20","2 × M25","4 × M20","4 × M25","4 × M32","6 × M25","6 × M32","—"]}],"righe":[["GHG 791 0101 R0002",1,0,2,5,42],["GHG 791 0101 R0001",1,0,2,3,42],["GHG 791 0201 R0001",1,1,4,7,42],["GHG 791 0201 R0003",1,1,5,4,42],["GHG 791 0201 R0006",1,1,4,5,42],["GHG 791 0101 R0019",1,0,2,2,42],["GHG 791 0201 R0002",1,1,4,8,42],["GHG 791 0201 R0007",1,1,4,6,42],["GHG 791 0101 R0069",1,0,0,5,42],["GHG 791 0101 R0068",1,0,0,2,42],["GHG 791 0201 R0016",1,1,1,1,42],["GHG 791 0101 R0003",1,0,3,0,42],["GHG 791 0101 R0004",2,0,3,0,42],["GHG 791 0101 R0005",1,0,3,0,42],["GHG 791 0101 R0008",2,0,3,0,42],["GHG 791 0101 R0006",2,0,3,0,42],["GHG 791 0201 R0010",1,1,6,0,42],["GHG 791 0201 R0008",1,1,6,0,42],["GHG 791 0201 R0011",2,1,6,0,42],["GHG 791 0101 R0010",2,0,3,0,42],["GHG 791 0201 R0009",2,1,6,0,42],["GHG 791 0201 R0014",1,1,6,0,42],["GHG 791 0101 R0009",1,0,3,0,42],["GHG 791 0201 R0015",2,1,6,0,42],["GHG 791 0201 R0013",2,1,6,0,42],["GHG 610 1953 R0102",0,2,7,9,42],["GHG 610 1953 R0101",0,2,7,9,42],["GHG 610 1953 R0105",0,2,7,9,42],["GHG 610 1953 R0104",0,2,7,9,42],["GHG 610 1955 R0102",0,2,7,9,42],["GHG 610 1955 R0101",0,2,7,9,42],["GHG 610 1953 R0103",0,2,7,9,42]],"descrizioni":["Ex e junction box GHG 791 01 for Zone 1/21, 4 x M25 cable gland, moulded polyamide – 4 x 4 mm² + 2x4 mm², 1 PE, pillar terminals, enclosure material: polyamide","Ex e junction box GHG 791 01 for Zone 1/21, 2 x M25 cable gland, moulded polyamide – 4 x 4 mm² + 2x4 mm², 1 PE, pillar terminals, enclosure material: polyamide","Ex e junction box GHG 791 02 for Zone 1/21, 6 x M25 cable gland, moulded polyamide – 6 x 4 mm² + 2x4 mm², 1 PE, pillar terminals, enclosure material: polyamide","Ex e junction box GHG 791 02 for Zone 1/21, 6 (entries only) x M20, 4 x M20 screw plug, internal brass frame – 8 x 4 mm² + 2x4 mm², 1 PE, pillar terminals, enclosure material: polyamide","Ex e junction box GHG 791 02 for Zone 1/21, 4 x M25 cable gland, moulded polyamide – 6 x 4 mm² + 2x4 mm², 1 PE, pillar terminals, enclosure material: polyamide","Ex e junction box GHG 791 01 for Zone 1/21, 4 (entries only) x M20, 2 x M20 screw plug, internal brass frame – 4 x 4 mm² + 2x4 mm², 1 PE, pillar terminals, enclosure material: polyamide","Ex e junction box GHG 791 02 for Zone 1/21, 6 x M32 cable gland, moulded polyamide – 6 x 4 mm² + 2x4 mm², 1 PE, pillar terminals, enclosure material: polyamide","Ex e junction box GHG 791 02 for Zone 1/21, 4 x M32 cable gland, moulded polyamide – 6 x 4 mm² + 2x4 mm², 1 PE, pillar terminals, enclosure material: polyamide","Ex e terminal box GHG 791 01 for Zone 1/21, 4 x M25 cable gland, drilled enclosure – 4 x 2.5 mm² + 2x2.5 mm², 1 PE, spring-clamp terminals, enclosure material: polyamide","Ex e terminal box GHG 791 01 for Zone 1/21, 4 (entries only) x M20, 2 x M20 screw plug, internal brass frame – 4 x 2.5 mm² + 2x2.5 mm², 1 PE, spring-clamp terminals, enclosure material: polyamide","Ex e intermediate motor terminal box GHG 791 02 for Zone 1/21, 1 x M32 trumpet-shaped gland, 1x M25 cable gland, drilled enclosure – 4 x 4 mm² + 1x4 mm², 1 PE, screw terminals, enclosure material: polyamide","Ex e terminal box GHG 791 01 for Zone 1/21, 1 x M25 cable gland, 1x M25 multiple cable gland, drilled enclosure – 6 x 2.5 mm² + 2x2.5 mm², 1 PE, screw terminals, enclosure material: polyamide","Ex i terminal box GHG 791 01 for Zone 1/21, 1 x M25 cable gland, 1x M25 multiple cable gland, drilled enclosure – 6 x 2.5 mm² + 2x2.5 mm², 1 PE, screw terminals, enclosure material: polyamide","Ex e terminal box GHG 791 01 for Zone 1/21, 1 x M25 cable gland, 2x M12 cable gland, drilled enclosure – 6 x 2.5 mm² + 2x2.5 mm², 1 PE, screw terminals, enclosure material: polyamide","Ex i terminal box GHG 791 01 for Zone 1/21, 1 x M25 cable gland, 1x M25 multiple cable gland, drilled enclosure – 6 x 2.5 mm² + 2x2.5 mm², 1 PE, spring-clamp terminals, enclosure material: polyamide","Ex i terminal box GHG 791 01 for Zone 1/21, 1 x M25 cable gland, 2x M12 cable gland, drilled enclosure – 6 x 2.5 mm² + 2x2.5 mm², 1 PE, screw terminals, enclosure material: polyamide","Ex e terminal box GHG 791 02 for Zone 1/21, 1 x M25 cable gland, 4x M12 cable gland, drilled enclosure – 12 x 2.5 mm² + 2x2.5 mm², 1 PE, screw terminals, enclosure material: polyamide","Ex e terminal box GHG 791 02 for Zone 1/21, 1 x M25 cable gland, 1x M32 multiple cable gland, drilled enclosure – 12 x 2.5 mm² + 2x2.5 mm², 1 PE, screw terminals, enclosure material: polyamide","Ex i terminal box GHG 791 02 for Zone 1/21, 1 x M25 cable gland, 4x M12 cable gland, drilled enclosure – 12 x 2.5 mm² + 2x2.5 mm², 1 PE, screw terminals, enclosure material: polyamide","Ex i terminal box GHG 791 01 for Zone 1/21, 1 x M25 cable gland, 2x M12 cable gland, drilled enclosure – 6 x 2.5 mm² + 2x2.5 mm², 1 PE, spring-clamp terminals, enclosure material: polyamide","Ex i terminal box GHG 791 02 for Zone 1/21, 1 x M25 cable gland, 1x M32 multiple cable gland, drilled enclosure – 12 x 2.5 mm² + 2x2.5 mm², 1 PE, screw terminals, enclosure material: polyamide","Ex e terminal box GHG 791 02 for Zone 1/21, 1 x M25 cable gland, 4x M12 cable gland, drilled enclosure – 12 x 2.5 mm² + 2x2.5 mm², 1 PE, spring-clamp terminals, enclosure material: polyamide","Ex e terminal box GHG 791 01 for Zone 1/21, 1 x M25 cable gland, 2x M12 cable gland, drilled enclosure – 6 x 2.5 mm² + 2x2.5 mm², 1 PE, spring-clamp terminals, enclosure material: polyamide","Ex i terminal box GHG 791 02 for Zone 1/21, 1 x M25 cable gland, 4x M12 cable gland, drilled enclosure – 12 x 2.5 mm² + 2x2.5 mm², 1 PE, spring-clamp terminals, enclosure material: polyamide","Ex i terminal box GHG 791 02 for Zone 1/21, 1 x M25 cable gland, 1x M32 multiple cable gland, drilled enclosure – 12 x 2.5 mm² + 2x2.5 mm², 1 PE, spring-clamp terminals, enclosure material: polyamide","Mounting plates size 1 – pipe mounting","Mounting plates size 1 – wall mounting","Mounting plates size 2 – pipe mounting","Mounting plates size 2 – wall mounting","Protective canopy size 2 – for mounting plate size 2","Protective canopy size 1 – for mounting plate size 1","Mounting plates size 1 – trellis mounting"],"opzioni":[["How to read the code","The code shown is the Eaton CEAG order number from the current price list. For other versions or accessories not listed, contact us."]],"sprite":{"url":"https://cdn.prod.website-files.com/6aa55eca30c5bd4a1e486a4c/6ada3d0b94066b8fc4df8a57_ceag-varianti-sprite.jpg","colonne":10,"lato":200}}
No items found.
No applications listed.