Services
Tools
Products
>
Solenoid valves
>
Coils, plug connectors and plates for solenoid valves – Range of 39 models
Solenoid valves
automazione-valvole-elettrovalvole

Coils, plug connectors and plates for solenoid valves – Range of 39 models

Standard and Ex coils, plug connectors and adapter plates for NAMUR and in-line solenoid valves: match voltage, wiring and interface without changing the valve.

ATEX
CE
Description
Technical Specifications
Applications
Download
Datasheets

Spare parts and add-ons for solenoid valves

This family brings together the parts used to configure or upgrade a NAMUR or in-line solenoid valve without replacing it: coils for different voltages and types of protection, plug connectors for wiring, and plates that adapt the valve to the actuator interface.

Standard coils are available for direct current from 12 to 110 V (3 W) and alternating current from 24 to 230 V (5 VA), with or without plug connector. For potentially explosive atmospheres there are Ex ia, Ex ec and Ex db mb coils, supplied with a plug connector and carrying the marking given in the technical data.

The plug connectors cover industrial forms A and B, versions with LED and varistor against voltage peaks, M12 quick connection and UL-certified models. The plates complete the installation: a distance plate for 30 mm wide coils, adapter plates between G1/4 and G1/2 NAMUR interfaces and a plate that converts a NAMUR valve into an in-line valve.

  • DC coils from 12 to 110 V and AC coils from 24 to 230 V
  • Coils for zones 1/21 (Ex ia, Ex db mb) and zones 2/22 (Ex ec)
  • Form A (M20x1.5), form B (M16x1.5), M12 and PG9 UL connectors
  • 10 mm NAMUR adapter plates and 5 mm distance plate
Zone 1
Explosive gas atmosphere likely to occur in normal operation
Zone 2
Explosive gas atmosphere unlikely to occur and, if it does, only for a short period
Zone 21
Explosive dust atmosphere likely to occur in normal operation
Zone 22
Explosive dust atmosphere unlikely to occur and, if it does, only for a short period
# General Type: Coils, plug connectors and plates for solenoid valves Available models: 39 # Standard coils DC voltages: 12, 24, 48, 110 V (3 W) AC voltages: 24, 48, 115, 230 V (5 VA) Version: with or without plug connector # Ex ia coil Gas marking (zone 1): II 2G Ex ia IIB/IIC T6 Gb Dust marking (zone 21): II 2D Ex tb IIIC T80°C Db Voltage: 24–28 V DC (0.8–1.6 W) # Ex ec coil Gas marking (zone 2): II 3G Ex ec IIC T5 Gc Dust marking (zone 22): II 3D Ex tc IIIC T95°C Dc Voltages: 24 V DC (3 W); 110 and 230 V AC (5 VA) # Ex db mb coil Gas marking (zone 1): II 2G Ex db mb IIC Tx Gb Dust marking (zone 21): II 2D Ex tb IIIC Tx°C Db DC voltages: 12, 24, 48 V (3 W) AC voltages: 24, 48, 115, 230 V (3.2 VA) Connector: PG9 for cable Ø 6–8 mm # Plug connectors Standard form B: M16x1.5 entry, cable Ø 6–8 mm Form B with LED and varistor: M16x1.5 entry, cable Ø 4–8 mm, 24/110/230 V Form B M12: quick connection Form A: M20x1.5 entry, cable Ø 8 mm PG9 with UL certification: cable Ø 4–10 mm PG9 UL with red LED: cable Ø 6–8 mm, 24 V # Plates Distance plate: 5 mm thick, for NAMUR valves with 30 mm wide coils Adapter plates: 10 mm thick, from G1/4 to G1/2 NAMUR interface and vice versa Conversion plate: from NAMUR to in-line, G1/4 ports
{"modelli":{"f":[["Component",["Coil","Plug connector","Plate"]],["Type of protection",["Standard (safe area)","Ex ia","Ex ec","Ex db mb"]],["Voltage",["12 V","24 V","48 V","110 V","115 V","230 V"]],["Current type",["Direct (DC)","Alternating (AC)"]]],"r":[["","Standard coil without plug connector, 12 V DC, 3 W",[[0],[0],[0],[0]],0,"1",""],["","Standard coil without plug connector, 24 V DC, 3 W",[[0],[0],[1],[0]],0,"1",""],["","Standard coil without plug connector, 48 V DC, 3 W",[[0],[0],[2],[0]],0,"1",""],["","Standard coil without plug connector, 110 V DC, 3 W",[[0],[0],[3],[0]],0,"1",""],["","Standard coil without plug connector, 24 V AC, 5 VA",[[0],[0],[1],[1]],0,"1",""],["","Standard coil without plug connector, 48 V AC, 5 VA",[[0],[0],[2],[1]],0,"1",""],["","Standard coil without plug connector, 115 V AC, 5 VA",[[0],[0],[4],[1]],0,"1",""],["","Standard coil without plug connector, 230 V AC, 5 VA",[[0],[0],[5],[1]],0,"1",""],["","Standard coil with plug connector, 12 V DC, 3 W",[[0],[0],[0],[0]],1,"1",""],["","Standard coil with plug connector, 24 V DC, 3 W",[[0],[0],[1],[0]],1,"1",""],["","Standard coil with plug connector, 48 V DC, 3 W",[[0],[0],[2],[0]],1,"1",""],["","Standard coil with plug connector, 110 V DC, 3 W",[[0],[0],[3],[0]],1,"1",""],["","Standard coil with plug connector, 24 V AC, 5 VA",[[0],[0],[1],[1]],1,"1",""],["","Standard coil with plug connector, 48 V AC, 5 VA",[[0],[0],[2],[1]],1,"1",""],["","Standard coil with plug connector, 115 V AC, 5 VA",[[0],[0],[4],[1]],1,"1",""],["","Standard coil with plug connector, 230 V AC, 5 VA",[[0],[0],[5],[1]],1,"1",""],["","Ex ia coil with plug connector, 24–28 V DC, 0.8–1.6 W (zones 1 and 21)",[[0],[1],[1],[0]],2,"1","II 2G Ex ia IIB/IIC T6 Gb · II 2D Ex tb IIIC T80°C Db"],["","Ex ec coil with plug connector, 24 V DC, 3 W (zones 2 and 22)",[[0],[2],[1],[0]],3,"1","II 3G Ex ec IIC T5 Gc · II 3D Ex tc IIIC T95°C Dc"],["","Ex ec coil with plug connector, 110 V AC, 5 VA (zones 2 and 22)",[[0],[2],[3],[1]],3,"1","II 3G Ex ec IIC T5 Gc · II 3D Ex tc IIIC T95°C Dc"],["","Ex ec coil with plug connector, 230 V AC, 5 VA (zones 2 and 22)",[[0],[2],[5],[1]],3,"1","II 3G Ex ec IIC T5 Gc · II 3D Ex tc IIIC T95°C Dc"],["","Ex db mb coil with PG9 plug connector (cable Ø 6–8 mm), 12 V DC, 3 W (zones 1 and 21)",[[0],[3],[0],[0]],4,"1","II 2G Ex db mb IIC Tx Gb · II 2D Ex tb IIIC Tx°C Db"],["","Ex db mb coil with PG9 plug connector (cable Ø 6–8 mm), 24 V DC, 3 W (zones 1 and 21)",[[0],[3],[1],[0]],4,"1","II 2G Ex db mb IIC Tx Gb · II 2D Ex tb IIIC Tx°C Db"],["","Ex db mb coil with PG9 plug connector (cable Ø 6–8 mm), 48 V DC, 3 W (zones 1 and 21)",[[0],[3],[2],[0]],4,"1","II 2G Ex db mb IIC Tx Gb · II 2D Ex tb IIIC Tx°C Db"],["","Ex db mb coil with PG9 plug connector (cable Ø 6–8 mm), 24 V AC, 3.2 VA (zones 1 and 21)",[[0],[3],[1],[1]],4,"1","II 2G Ex db mb IIC Tx Gb · II 2D Ex tb IIIC Tx°C Db"],["","Ex db mb coil with PG9 plug connector (cable Ø 6–8 mm), 48 V AC, 3.2 VA (zones 1 and 21)",[[0],[3],[2],[1]],4,"1","II 2G Ex db mb IIC Tx Gb · II 2D Ex tb IIIC Tx°C Db"],["","Ex db mb coil with PG9 plug connector (cable Ø 6–8 mm), 115 V AC, 3.2 VA (zones 1 and 21)",[[0],[3],[4],[1]],4,"1","II 2G Ex db mb IIC Tx Gb · II 2D Ex tb IIIC Tx°C Db"],["","Ex db mb coil with PG9 plug connector (cable Ø 6–8 mm), 230 V AC, 3.2 VA (zones 1 and 21)",[[0],[3],[5],[1]],4,"1","II 2G Ex db mb IIC Tx Gb · II 2D Ex tb IIIC Tx°C Db"],["","Standard form B plug connector, M16x1.5 entry, cable Ø 6–8 mm",[[1],[],[],[]],5,"1",""],["","Form B plug connector with LED and varistor, M16x1.5 entry, cable Ø 4–8 mm, 24 V",[[1],[],[1],[]],6,"1",""],["","Form B plug connector with LED and varistor, M16x1.5 entry, cable Ø 4–8 mm, 110 V",[[1],[],[3],[]],6,"1",""],["","Form B plug connector with LED and varistor, M16x1.5 entry, cable Ø 4–8 mm, 230 V",[[1],[],[5],[]],6,"1",""],["","Form B plug connector with M12 quick connection",[[1],[],[],[]],7,"1",""],["","Form A plug connector, M20x1.5 entry, cable Ø 8 mm",[[1],[],[],[]],8,"1",""],["","PG9 plug connector with UL certification, cable Ø 4–10 mm",[[1],[],[],[]],null,"1",""],["","PG9 plug connector with UL certification and red LED, cable Ø 6–8 mm, 24 V",[[1],[],[1],[]],null,"1",""],["","Distance plate 5 mm for NAMUR valves with 30 mm wide coils",[[2],[],[],[]],9,"2",""],["","Adapter plate 10 mm for G1/4 NAMUR valve on actuator with G1/2 NAMUR interface",[[2],[],[],[]],10,"2",""],["","Adapter plate 10 mm for G1/2 NAMUR valve on actuator with G1/4 NAMUR interface",[[2],[],[],[]],null,"2",""],["","Conversion plate from NAMUR valve to in-line valve with G1/4 ports",[[2],[],[],[]],null,"2",""]],"s":{"u":"https://cdn.prod.website-files.com/6aa55eca30c5bd4a1e486a4c/6ae3a7840d1593dcfddd24d6_mfv-bobine-connettori-piastre-elettrovalvole.jpg","c":11},"b":"https://cdn.prod.website-files.com/6aa55eca30c5bd4a1e486a4c/6ae3a74c1959fe50be87baa2_bobine-connettori-piastre-elettrovalvole-schede-tecniche.pdf#page=","p":"","nc":1}}
No items found.
No applications listed.
Coils, plug connectors and plates for solenoid valves – Range of 39 models