# General
Product type: Low-intensity LED obstruction light type A/B/E
Brand: Auer Signal (Austria)
Series: RDMOL
Models: RDMOL
Rated voltage: 110-240 V AC · 24 V AC/DC
Use: safe area (non-Ex)
# Technical data
Operating temperature: -30 °C / +60 °C
Duty cycle: 100 %
Housing: Ø 110 mm, Polycarbonate, UV stabilized
Lens: Polycarbonate, UV stabilized, ribbed inside
Leakage current: 0,003 A
Light source: LEDs
Beacon type: LED steady beacon or LED flashing beacon
Type of mounting: horizontal, vertical, Tube mounting, Wall mounting or any
Product standard: IEC/EN60947-5-1// UL60947-5-1// ICAO, Annex 14, Vol. 1 - Paragraph 6// EASA, CS–ADR-DSN Chapter Q
Impact resistance: IK08
Degree of protection: IP66 & UL Type 4/4x/13
{"v":1,"marca":"Auer Signal","colonne":[{"nome":"Model","valori":["RDMOL"]},{"nome":"Voltage","valori":["24 V AC/DC","110-240 V AC"]}],"righe":[["850 602 313",0,1,0],["850 602 405",0,0,0]],"accessori":[["850 520 900","RWD – Bracket for wall mounting of R-series beacons",1],["850 521 900","RWU – Bracket for wall mounting of R-series beacons",2],["850 590 900","RG1 – Flat seal for R-series bases for sealing onto smooth housings",3],["850 590 910","RG2 – Flat seal for mounting the RWD designer bracket on walls",4],["850 590 920","RKV – Cable gland M16 for R-series bases",5],["698 800 026","AKV – Cable gland M20x1,5",5]],"tp":"https://cdn.prod.website-files.com/6aa6f9c43abe1bc0a0cc39bd/","thumbs":["6af470cdb96f7898258e8f7f_.jpeg","6af470cfb96f7898258e8fdb_.jpeg","6af470cfb96f7898258e8fe2_.jpeg","6af470d0b96f7898258e8fee_.jpeg","6af470cfb96f7898258e8fba_.jpeg","6af470c4b96f7898258e8f46_.jpeg"],"sprite":{"url":"https://cdn.prod.website-files.com/6aa6f9c43abe1bc0a0cc39bd/6af470cdb96f7898258e8f7f_.jpeg","colonne":1}}